Presentation
Harmonic frequencies emission
Within ETSI standard
Spurious frequencies emission
within ETSI standard
Driving power
2W typical, with automatic increasing/
decreasing notice for optimal driving
power and protection against bad input
levels
RF output power range
1,000 to 10,000 W adjustable
INSTALLATION REQUIREMENTS
Power supply
• 208V - threephase Delta
• 400V - threephase WYE
• 230V monophase possible by paral-
lel connection of suppliers
Power consumption
14kW typical - 15kW max
Recommended wiring section
4sqmm / AWG11
Total current consumption
40A per phase @ 208 VAC
20A per phase @ 400 VAC
Current absorption may increase in case
of lower AC line voltage�
Overall efficiency
• 70-73% @ rated power
• 68-70% @ -3dB power
• 65% @ -6dB power
Power factor
> 0�95
COOLING SYSTEM
Cooling type
Forced air-cooling
Air flow
1,000 cbm/h typical (depending on
temperature)
ENVIRONMENT
Operating temperature
-5 to +45 °C / 23 to +113 °F
Operating humidity
95% @ 40 °C / 104 °F
Operatine altitude
<3,000 metres / <9840 feet
Storage temperature
-20 to +55 °C / -4 to +131 °F
Storage humidity
90% @ 55 °C / 131 °C
Storage altitude
<15,000 metres / <49,200 feet
TELECONTROL AND TELEMETRY
Remote control
Yes
SNMP
Yes
25
Preliminary
Содержание E10000X
Страница 3: ...3 Revision N Date Description 00 01 12 2016 First release Revision Preliminary...
Страница 6: ...6 Index...
Страница 10: ...10 Informative letter...
Страница 14: ...14 Identification...
Страница 30: ...30 User instructions...
Страница 50: ...50 User instructions...
Страница 54: ...54 User instructions...
Страница 58: ...58 User instructions...
Страница 60: ...60 WEB interface...
Страница 69: ...69 WEB interface 6 1 System Overwiev Network interface parameters Installed modules configuration...
Страница 72: ...72 WEB interface...
Страница 103: ...103 WEB interface Statistics are updated in real time Example of Cost Map in which 4 different bands are inserted...
Страница 104: ...104 WEB interface...