48
User instructions
Event
Code
Message
Description
STATUS
000
CORRECT WORKING
No error� The apparatus is working correctly�
The event “019 ON AIR” has an higher priority�
STATUS
001
SYSTEM RESET
The list of occurred alarms is under deleting
process� Active ones aren’t deleted�
WARNING
002
EEPROM CHKSUM ERROR
The data stored in memory is no longer relia-
ble� The apparatus will be restarted with de-
fault parameters�
ALARM
003
BLOCKED
The apparatus is blocked after that five resto-
re have been attempted� To restart it, a reset
command is required�
STATUS
004
STOP
The apparatus is in StandBy mode with no acti-
ve alarms, ready to work�
ALARM
005
-3dB CARRIER
The RF output power is less than half target po-
wer since one minute during the start up or five
seconds during the correct working�
ALARM
006
HIGH REF PWR
High reflected power is detected after that a
“Three Block Out” recovery protection has been
attempted�
ALARM
007
MIN 12V
The negative voltage reference is no longer re-
liable� The apparatus attempts the “Three Block
Out” recovery protection�
ALARM
008
RF AMP� FAULT
A failure is occurred in one or more RF amplifier
modules�
WARNING
009
RF AMP� FAULT DERATING
As above, but the RF output power is reduced
according to an algorithm�
WARNING
010
RF THERMAL DERATING
The temperature of one or more RF amplifier
modules is been too high so that the RF output
power is reduced according to an algorithm�
ALARM
011
RF OVER TEMPERATURE
The “RF THERMAL DERATING” failed and the ap-
paratus attempts the “Three Block Out” recove-
ry protection�
ALARM
012
PSU FAULT
A PSU malfunction is occurring�
WARNING
013
PSU CURRENT DERATING
One or more PSU overloads are occurred so that
the apparatus is reducing the RF power output
according to an algorithm�
ALARM
014
PSU OVER CURRENT
The apparatus was shut down in a minute since
the current derating didn’t decrease�
WARNING
015
PSU THERMAL DERATING
One or more PSU overheatings are occurred so
that the apparatus is reducing the RF output
power according to an algorithm�
ALARM
016
PSU OVER TEMPERATURE
The temperature of one or more PSU have been
too high so that apparatus has been shut down�
ALARM
017
PSU COMM TIMEOUT
The RS485 internal bus dedicated to the com-
munication between CPU and PSU isn’t working
correctly�
STATUS
018
EXTERNAL INTERLOCK
The interlock circuit is open and the apparatus
is blocked�
STATUS
019
ON AIR
The apparatus works correctly�
STATUS
020
POWER UP
RF output power increase is occurring�
STATUS
021
POWER DOWN
RF output power decrease is occurring�
WARNING
022
PSU THERMAL DERATING/FAULT
One or more PSU are performing a thermal de-
rating by reducing the current supplied�
WARNING
023
PSU LOW POWER
One or more PSU are in thermal derating so
that the RF output power is reduced�
ALARM
024
PSU RF OFF
The RF section has been turned off so that the
fans can quickly cool the apparatus�
STATUS
025
WORKING MODE COMBINED
The apparatus works in a combined transmitter�
WARNING
026
SWR FOLDBACK
High reflected power has been detected so that
the apparatus is adjusting the RF output power
according to an algorithm�
STATUS
030
OVER 2/3 CARRIER
The RF output power is rising up to 2/3 of the
target after which a “-3dB” alarm has occurred�
Содержание E10000X
Страница 3: ...3 Revision N Date Description 00 01 12 2016 First release Revision Preliminary...
Страница 6: ...6 Index...
Страница 10: ...10 Informative letter...
Страница 14: ...14 Identification...
Страница 30: ...30 User instructions...
Страница 50: ...50 User instructions...
Страница 54: ...54 User instructions...
Страница 58: ...58 User instructions...
Страница 60: ...60 WEB interface...
Страница 69: ...69 WEB interface 6 1 System Overwiev Network interface parameters Installed modules configuration...
Страница 72: ...72 WEB interface...
Страница 103: ...103 WEB interface Statistics are updated in real time Example of Cost Map in which 4 different bands are inserted...
Страница 104: ...104 WEB interface...