49
User instructions
Event
Code
Message
Description
WARNING
034
TEMPERATURE SENSOR ERROR
If the thermal probes installed are more than
one, it means the fault of one of these because
its read value is significantly different from the
expected one�
ALARM
035
PWR FORWARD OSCILLATION
RF output power oscillation is detected and the
apparatus attempts the “Three Block Out” reco-
very protection�
ALARM
036
THREE BLOCK OUT
The malfunction has not disappeared during
the automatic protection time and the appara-
tus was stopped�
WARNING
037
USER ENV TEMP OUT LIMIT
The user-defined environmental temperature
limits in “User Alarms Data” have been excee-
ded�
WARNING
038
USER RF TEMP OUT LIMIT
The user-defined RF temperature limits in “User
Alarms Data” have been exceeded�
WARNING
039
USER PSU TEMP OUT LIMIT
The user-defined PSU temperature limits in
“User Alarms Data” have been exceeded�
WARNING
040
USER RF CURRENT OUT LIMIT
The user-defined RF current limits in “User
Alarms Data” have been exceeded�
WARNING
041
USER PSU CURRENT OUT LIMIT
The user-defined PSU current limits in “User
Alarms Data” have been exceeded�
WARNING
042
USER FRW PWR OUT LIMIT
The user-defined RF forward power limits in
“User Alarms Data” have been exceeded�
WARNING
043
USER RFL PWR OUT LIMIT
The user-defined RF reflected power limits in
“User Alarms Data” have been exceeded�
ALARM
044
OUT PWR NOT VERIFIED
The RF output power measurement is not re-
liable�
STATUS
045
UPS ACTIVE
The apparatus works by drawing current from
the UPS�
ALARM
046
SHUNT COMM TIMEOUT
Internal serial communication timeout� The ap-
paratus has stopped working�
WARNING
047
WARNING TEMPERATURE SENSOR
A thermal probe is unreliable and its reading
is discarded�
ALARM
049
DRAIN VOLTAGE TOO LOW
VDS voltage too low� The amplifier section has
been stopped and will remain so until the di-
sappearance of the cause�
WARNING
050
OVER FRW PWR ERROR
An overshoot of RF output power respect to the
target is occurred�
WARNING
051
PSU VOLTAGE DERATING
One or more PSU are in voltage derating�
WARNING
052
PSU NET OVER VOLTAGE
Mains voltage too high�
STATUS
053
PILOT PWR GOOD
The RF input power level is correct�
WARNING
054
INCREASE PILOT PWR
The RF input power level is to low but not dan-
gerous and must be increased�
WARNING
055
DECREASE PILOT PWR
The RF input power level is to high but not
dangerous and should be decreased�
ALARM
056
BAD INPUT RF PROTECTION
RF input power level out of limit� The external
modulator has been disconnected�
WARNING
059
BATTERY LOW
The CPU backup battery is low� In case of no
mains, the clock will lose settings�
WARNING
060
REFERENCE VOLTAGE ERROR
The internal reference voltage is no longer re-
liable and the measurements will be incorrect�
Some wrong alarms or warnings could be sent�
WARNING
062
DRAIN VOLTAGE CONTROL ERROR
VDS voltage is more than 4V different from the
expected value� The adjustment is fixed at the
last valid value� It restarts when the difference
becomes less than 4V�
WARNING
065
RTC FAULT
The clock says a wrong time and it isn’t possible
to cerrect automatically� Some settings, such as
“clock power target”, will not run correctly�
STATUS
066
RTC USER UPDATED
The user has updated the internal clock�
STATUS
067
RTC AUTOMATIC RECOVERY
The apparatus has updated the internal clock
automatically�
Содержание E10000X
Страница 3: ...3 Revision N Date Description 00 01 12 2016 First release Revision Preliminary...
Страница 6: ...6 Index...
Страница 10: ...10 Informative letter...
Страница 14: ...14 Identification...
Страница 30: ...30 User instructions...
Страница 50: ...50 User instructions...
Страница 54: ...54 User instructions...
Страница 58: ...58 User instructions...
Страница 60: ...60 WEB interface...
Страница 69: ...69 WEB interface 6 1 System Overwiev Network interface parameters Installed modules configuration...
Страница 72: ...72 WEB interface...
Страница 103: ...103 WEB interface Statistics are updated in real time Example of Cost Map in which 4 different bands are inserted...
Страница 104: ...104 WEB interface...