38
MAINTENANCE
Element4 Gas Fireplaces Rev #07022020
European
Home
.com
WARNING
Installation and maintenance must be performed by an authorized qualified installer, service agency or gas supplier.
TURN OFF THE GAS before servicing the appliance. It is recommended that a qualified service technician perform an
appliance check-up/service once a year.
Any safety screen or guard removed for servicing MUST BE REPLACED before operating this appliance.
DO NOT USE this appliance if any part has been under water. Immediately call a qualified service technician to inspect the
unit and to replace any part of the control system and any gas valve that has been under water.
Any alteration to the product that causes soot or carbon to form and results in damage is not the responsibility of the
manufacturer.
Inspect the external vent cap on a regular basis to make sure that no debris, plants, trees, or shrubs are interfering with the
air flow.
BURNER MAINTENANCE
The flames from the burner should be visually checked. The flame should have a blue base and yellow tops and be candle-like in
appearance.
PILOT MAINTENANCE
The pilot flame must be visually checked. The pilot flame must always be present when the appliance is in operation and should
appear as shown in Figure 106 (with hearth panel removed.)
The pilot has two distinct flames, one engulfing the thermocouple on its left, the other reaching across to the burner.
The area around the pilot should be inspected for cleanliness. Lint or foreign material must be removed with a brush or vacuum.
Figure 74