General menu structure Ceta series

Basic display

Prog

Esc

01

Menu 01

02

Menu 02

+

-

27

Calibration

28

Relay test

02:01

Parameter 01

02:02

Parameter 02

02:nn

Last parameter

+

-

+

-

+

-

+

-

Prog

Select menu level

Select parameters

Esc

Value 1

Prog

Value 2

+

-

Value n

+

-

Set parameter value

Prog

Return
without
saving

Return
and save

Esc

BA_CETA100_EbV_EN_0450021000_0931-10.book  Seite 3  Dienstag, 25. August 2009  3:33 15

Содержание Ceta 100

Страница 1: ...Operating manual 100 Differential temperature control Version 0931 10 Art 0450021000 BA_CETA100_EbV_EN_0450021000_0931 10 book Seite 1 Dienstag 25 August 2009 3 33 15 ...

Страница 2: ...eclaration of conformity 13 Technical Data 14 Liability 14 Disposal 14 Elektronikbau und Vertriebs GmbH Heisterner Weg 8 12 D 57299 Burbach This document may not be reproduced nor disclosed to third parties particularly competitors in original or copy form without our prior explicit consent The document is subject to our proprietary rights and copyrights Contents BA_CETA100_EbV_EN_0450021000_0931 ...

Страница 3: ...cordance with state of the art technology and approved safety regulations Nevertheless using the unit can cause danger to the user or third persons or damage to the unit and other assets The unit must be used exclusively as differential temperature controller Safety All electrical connections safety measures and protections have to be carried out by an authorised professional electrician according...

Страница 4: ...t higher menu level Esc Long Return to basic display 2 Version display when starting 3 Basic display c 100 Type designation 24 02 Version display due to update it can differ from example shown 80 5 C Temperature heat supplier e g collector or solid fuel boiler 44 0 C Temperature heat storage tank ΔT1 Display pump function BA_CETA100_EbV_EN_0450021000_0931 10 book Seite 2 Dienstag 25 August 2009 3 ...

Страница 5: ...7 Calibration 28 Relay test 02 01 Parameter 01 02 02 Parameter 02 02 nn Last parameter Prog Select menu level Select parameters Esc Value1 Prog Value 2 Value n Set parameter value Prog Return without saving Return and save Esc BA_CETA100_EbV_EN_0450021000_0931 10 book Seite 3 Dienstag 25 August 2009 3 33 15 ...

Страница 6: ... 01 Heat capacity 08 02 Heat balance 08 03 03 03 Bus address 08 01 Delta T Oper mode 08 02 Switch on differ 08 03 Switch off differ 08 09 Burner block heat generator 08 10 Inhibition heat generator 08 11 Heat balance On Off 27 01 Calib sensor F1 27 02 Calib sensor F2 27 03 Calib sensor F3 28 01 Relay test output R1 Prog ESC Prog ESC Prog ESC Prog ESC Prog ESC X1 X1 ESC X2 X2 X3 X3 X3 Pump On Off B...

Страница 7: ... Min temp heat supplier 08 06 Max temp heat supplier 08 07 Fin switch off temp heat supplier 08 08 Max temp heat stor tank 08 12 Volume flow HT medium 08 13 Density HT medium 08 14 Heat capacity HT medium 08 15 Reset counter 03 09 Code heating specialist 03 10 Reset parameter 03 07 X3 X3 X3 Anti blocking prot pump BA_CETA100_EbV_EN_0450021000_0931 10 book Seite 5 Dienstag 25 August 2009 3 33 15 ...

Страница 8: ...available 08 07 Pump operating hours Number of pump operating hours 08 08 Pump starts Number of pump starts Display Designation Description 03 01 Code entry Setting range 0 999 Factory setting 0 Function Show parameters marked with X3 03 02 Automatic set function 0 OFF no automatic sensor detection X3 1 ON automatic sensor detection 03 03 Bus address Setting range 21 25 X3 Factory setting 21 Funct...

Страница 9: ...s whether heat balancing is to be performed by a return flow sensor additional parameters 08 02 Switch on difference Setting range Switch off differential 3K 30K Factory setting 10K Function If temperate difference between sensors of heat supplier F3 and heat storage tank F1 is larger than set value the pump switches on 08 03 Switch off difference Setting range 2K Switch on differential 3K Factory...

Страница 10: ...tting range OFF 50 110 C Factory setting 75 C Function Irrespective of switching differentials the pump performs a forced switch off after the sensor of heat storage tank F1 has exceeded the set value This switch off takes priority over functions 08 07 and 08 06 08 09 Burner block Heat generator Setting range 0 2 X2 Factory setting 1 Function 0 OFF 1 Burner block when pump is active 2 Burner block...

Страница 11: ... heat transfer medium according to manufacturer s information 08 15 Reset counter Setting range 0 no reset 1 reset counter Factory setting 0 Function When value is changed to 1 and confirmed all counters heat balance operating hours and starts are reset Display Designation Description 27 01 Calibration F1 Setting range 5K 5K Factory value 0K Function Correction of measured sensor value on Input he...

Страница 12: ...nergised before opening it 1 Remove terminal area cover from casing 2 For mounting first put a screw into the wall 3 Hang controller into the opening 4 Use controller as template for the other screw holes 1 Insert mounting feet into rail mount opening 2 Lock hook in place by pushing down BA_CETA100_EbV_EN_0450021000_0931 10 book Seite 10 Dienstag 25 August 2009 3 33 15 ...

Страница 13: ...l boiler has interruption 1 C Sensor heat storage tank has short circuit 230V connections Low voltage connections L Phase 230V mains 1 L1 230V pump connection Connections without function Connections without function N Neutral 230V mains pump Connections without function Earthing Bus connections for networking see parameter 03 03 Connections without function Connections without function F1 Sensor ...

Страница 14: ...connection repair if necessary replace fuse T C R kOhm T C R kOhm 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 1 155 1 194 1 232 1 271 1 309 1 347 1 385 1 423 1 461 1 498 1 536 1 573 1 611 1 648 1 685 1 722 1 758 1 795 1 832 1 868 1 905 1 941 10 12 14 16 18 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 1 783 1 812 1 840 1 869 1 898 1 928 2 002 2 078 2 155...

Страница 15: ...rective is proven by complete adherence to the following standards EMV Requirements for household appliances electric tools and similar devices DIN EN 55014 1 2003 Part1 Transient emission DIN EN 55014 2 2002 Part 2 Immunity EMV Limit values DIN EN 61000 3 2 2002 Part 3 2 Limit values for harmonic current emissions DIN EN 61000 3 3 2002 Part 3 3 Limitation of voltage fluctuations and flicker Autom...

Страница 16: ...ith applicable statutory regulations of the corresponding country Mains voltage 230V 6 10 Rated frequency 50 60Hz Power input max 2 1VA Fuse 6 3A Output relay contact load 2 2 A Ambient temperature 10 50 C Storage temperature 25 80 C Degree of protection IP 30 Protection class according to EN 60730 II CE compliance 89 336 EEC Casing dimensions 145 5 x 161 x 48 mm W x H x D Casing material ABS V0 W...