Parameter description
27 Sensor calibration
28 Relay test
08:12
Volume flow HT-
medium
Setting range:
0.0 … 30 l/min
Factory value:
0.0 l/min
Function:
Here the volume flow is set in litre/minute when calculating flow
rate, according to respective pump capacity.
08:13
Density HT-medium
Setting range:
0.8 … 1.2 kg/l
Factory setting:
1.05 kg/l
Function:
Using this parameter, the density of the heat transfer medium is
entered in kilogramme per litre, according to manufacturer's data.
08:14
Heat capacity HT-
medium
Setting range:
2.0 … 5.0 kJ/kgK
Factory value:
3.6 kJ/kgK
Function:
This setting value is used to enter the specific heat capacity of
the heat transfer medium according to manufacturer's
information.
08:15
Reset counter
Setting range:
0 = no reset, 1 = reset counter
Factory setting:
0
Function:
When value is changed to 1 and confirmed, all counters (heat
balance, operating hours and starts) are reset.
Display
Designation
Description
27:01
Calibration F1
Setting range:
-5K … +5K
Factory value:
0K
Function:
Correction of measured sensor value on
Input heat storage tank F1
27:02
Calibration F2
See 27:01 on input return F2
27:03
Calibration F3
See 27:01 on input heat supplier F3
Display
Designation
Description
28:01
Test pump output
Setting range:
-0 = OFF
1 = ON
Factory value:
0
Function:
By changing the value, the output switches on and off (test
function), independent of function.
Display
Designation
Description