12
Error codes
In case of a malfunction, an error code is indicated on the digital multifunction display
54
and the corresponding error description
appears on the LCD display
50
. As long as an error code is indicated, welding operation is not possible.
Code lock function
The lock function in menu Extras is secured with a code lock. A three-digit code must be entered before the lock function can be
changed. Only after the correct code is entered, the lock function can be altered. After leving the menu, a new code number can
be set or the old code number is acknowledged. Code "000" is the default (factory setting) number.
Procedure:
switch to menu Extras, lock function
pressing button
44
(minus) or
48
(plus) question „change parameter ?“ is displayed
acknowledge with button
51
(up)
set three-digit code number with button
44
(minus),
48
(plus) or encoder
53
acknowledge the code number with button
51
(up)
set desired lock function number with buttons
44
(minus) or
48
(plus)
leave menu with button
46
(END)
if requested, set a new code number with buttons
44
(minus),
48
(plus) or encoder
53
acknowledge the code number with button
51
(up)
Code Error description
Remark
Remedy
E00
no Prog
No welding parameters for the selected
material-wire-gas combination (no sensible
combination)
Choose a different material-wire-gas
combination
E01
Thermal overload
The system has been overheated
Allow the system to cool down in standby;
check the ventilation
E02
Mains overvoltage
Mains voltage too high
Check mains voltage
E03
Overcurrent
Output current too high
Notify service technician
E04
Air-cooling error
Flow rate of air too low
Clean the air intake
9
; check fan
E05
Faulty cooling circuit
No or too little flow rate of water
Check level of cooling liquid and coolant filter
E06
Overvoltage
Output voltage too high
Notify service
E07
EEProm checksum error Adjustment data faulty or not available
Switch system off and then on again
E08
Wire feed / tacho
Current input from feed motor too high
No tacho signal available
Blow out torch package with compressed air
and check wire feed unit
E09
Error v/a measuring
Faulty current / voltage measuring systems
Notify service
E10
Torch socket / cable
Faulty torch switch cable or torch switch
socket
Check torch
E11
Remote control socket
Faulty remote control or socket of remote
control
Check remote control
E12
Communication process
Defective communication CAN-Bus (process) Switch system off and then on again
E13
Error, temperature sensor Thermo sensor not operative
Notify service
E14
Supply voltage
Internal supply voltage too low
Check mains voltages
E16
Overcurrent protection 1 Allowable maximum power supply of power
unit 1 too high
Notify service
E18
Overload protection
Safety switch device for protection of
electrical components
Allow the system to cool down in standby
E20
Overvoltage secondary
Output voltage too high
Notify service
E21
Output voltage / current
Power unit delivers voltage / current without
drive
Notify service
E22
Mains undervoltage 1
Mains voltage at power unit 1 too low
Check mains voltages
E23
Mains overvoltage
Mains voltage too high
Check mains voltages
E24
Overcurrent protection 2 Power supply of power unit 2 too high
Notify service
E25
Power-module detection Power unit not being recognized or unallowa-
ble combination of power units
Notify service
E27
No program (DSP)
Welding programs faulty or not available
Notify service
E30
Mains undervoltage 2
Mains voltage at power unit 2 too low
Check mains voltages
E31
Communication error
Faulty communication CAN-Bus (master)
Switch system off and then on again