9
12 Menu Structure
Main Level
Level 1
Level 2
Remark
Gas pre-flow
0 – 10 sec.; not in electrode mode
Start current
20 % – 200 % of the welding current
Start current time
0 – 10 sec.; not in 4-stroke mode
Twin pulse frequency
0,5 – 5 Hz; only in Twinpulse mode
Twin pulse current change
5 – 50 % of the welding current; only in Twinpulse mode
Twin pulse relation
20 % – 80 %; only in Twinpulse mode
Welding current
Adjustment range depends on the selected material-wire-
gas combination
Downslope
10 – 990 A/sec.; not in electrode mode, only when downs-
lope = on
Final current
10 % – 100 % of the welding current; not in electrode mode,
only when slope = on or in 4-stroke
Final current time
0 – 10 sec.; not in electrode mode, only for slope = on
Wire burnback time
20 % – 300 % of the programmed value; not in electrode
mode
Gas post-flow
20 % – 200 % of the programmed value; not in electrode
mode
Arc length correction
60 % – 140 % of the programmed value
Inductor effect
20 % – 200 % of the programmed value; only in normal
mode (short arc)
+/- 40% in manual mode (see “Manual mode” on page 11)
Arc dynamic
0 % – 100 % of the programmed value; only in electrode
mode
Job selection, indication of
set and job name
Set and job name are indicated only in Tiptronic mode
upon actuation of the “TT Enter” push-button
47
or the “Tip-
tronic” push-button
49
Edit mode for set and
job name
Move the cursor with the
and
push-buttons
51
;
change the character with the pushbuttons
48
(+) and
44
(-
)
Extras
1Machine data
Operating system Master
Version number, operating system Master
Operating system Process Version number, operating system process
Operating system DMRs
Version number, motor assembly (-ies)
Welding program version
Version number, welding programs
Operating hour counter
Indication of the welding duration in h, min, sec
Configuration
Machine type and the recognized power module (with max.
current ) are indicated alternately
2 Diagnosis
Last error message
Indication of the last three error messages from the error
memory (0 = last error, 2 = oldest error)
Module temperatures
Temperatures of the power modules in °C
Operating voltages
Indication of the operating voltages (15 V / 24 V) of the
E-assembly DP-MAPRO
Flow rate, cooling unit
Indication of the coolant flow rate in l/min
3 Language
Selection of the menu language
4 Display contrast
Contrast setting of the LCD display
5 Mode cooling system
0 normal
cooling unit switches on, as soon as an arc is ignited
1 on
cooling unit runs constantly
2 off
cooling unit is deactivated
6 Lock function
0
All free
1
Welding current, mode and Tiptronic on/off free
2
Tiptronic on/off, job selection free
3
All locked except menu selection, gas and pump test
7 Arc lenght control
voltage
correct arc lenght with rotary pulse encoder
58
wire
correct wire speed with rotary pulse encoder
58
8 Robot interface
Menu item is only visible when the machine is equipped
with a robot interface (further details about setup/configura-
tion see operation manual INT)