background image

 -                                     MY575 SPOT 

 

 
Default settings shaded. 

 

Main 

menu 

Sub menu 

Extension 

Display 

Function 

VALU 

A001~A511 (AXXX) 

DMX address setting 

ADDR 

SLAV 

ON/OFF     (SLAV) 

Slave setting 

ALON      (AU-A) 

Automatic Program Run   

in Stand Alone mode 

AUTO 

MAST      (AU-M) 

Automatic Program Run   

as Master 

ALON      (SO-A) 

Sound-controlled Program 

Run in Stand Alone mode 

RUN 

SOUN 

MAST      (SO-M) 

Sound-controlled Program 

Run as Master 

VALU 

D–00 ~ D-30   
(DXXX) 

Display the DMX 512 value 

of each channel 

RDIS 

ON/OFF 180º 

Reverse 

display 

0 MODE 

DISP 

CLDI 

ON/OFF 

Shut off LED display 

OPEN 

ON/OFF  

Lamp 

on/off 

ONLI 

ON/OFF  

Lamp on/off via controller 

1 LAMP 

DELA 

D–00 ~ D-59,D-15 

 

Delay lamp on 

RPAN 

ON/OFF  

Pan 

Reverse 

VER 

V1.0-V9.9  

Software 

Version 

LODA 

ON/OFF 

 

Restore Default factory setting 

REST 

ON/OFF  

Reset 

DEGRE 

540/630  

Pan 

Degrees 

16BI 

8/16 

 

8 or 16 Bit control 

2 SET 

RTIL 

ON/OFF  

Tilt 

Reverse 

LADJ 

ON/OFF  

Lamp 

adjustment 

3 ADJU 

TEST 

T–01 ~ T–30 

 

Test function of each channel 

MATI 

0000~9999 (hours) 

 

Fixture running time 

LATI 

0000~9999 (hours) 

 

Lamp running time 

CLMT 

ON/OFF 

 

Clear fixture time 

4 TIME 

CLLT 

ON/OFF  

Clear 

lamp 

time 

STEP 

S–01 ~ S–48 

 

Steps of Program Run 

C–01 ~ C–30 

01XX (00~FFH) 
30XX (00~FFH) 

Edit the channels of each 

scene/cue/look 

TIME (sec.) 

T – – X (1~9) 

Time for each scene/cue/look 

5 EDIT 

SC01 

 ~  

SC48 

CNIN 

ON/OFF Edit 

program 

via 

controller 

 

Содержание MY 575.3

Страница 1: ...MY 575 3 USER MANUAL V1 03...

Страница 2: ...r 0 15Hz or random strobe dimmer mechanical adjustable from 0 to 100 colors 2 color wheels color wheel 1 has 7 dichroic filters plus white with rainbow effect color wheel 2 4 dichroic filters plus whi...

Страница 3: ...ry hot to touch Please keep MY575 away from children and the general public Please be intelligent and use common sense when operating MY575 General Guidelines MY575 is a lighting fixture for professio...

Страница 4: ...A B C on the bottom of the housing holding the plate under which the lamp is located Carefully remove the metal plate 2 Carefully insert the lamp into the socket Please remember the lamp is polarized...

Страница 5: ...ing used Periodic safety inspections should be done of MY575 as the fixture does move If you do not have the qualifications and experience do not attempt the installation Improper installation can res...

Страница 6: ...ng the correct number on the display located on the base of MY575 You can set the same starting address for all fixtures or group of fixtures like all the MY575s in your plot or you can make different...

Страница 7: ...wn buttons to change the address 2 The default for the lamp striking is from the board channel 14 The fixture s lamp will not just start up when you turn on the fixture The main menu is accessed by pr...

Страница 8: ...n off ONLI ON OFF Lamp on off via controller 1 LAMP DELA D 00 D 59 D 15 Delay lamp on RPAN ON OFF Pan Reverse VER V1 0 V9 9 Software Version LODA ON OFF Restore Default factory setting REST ON OFF Res...

Страница 9: ...T DN to return to main menu Slave setting With this function you can define the device as slave 1 Select SLAV by pressing the UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select O...

Страница 10: ...el If you select D 14 the display will only show the DMX value of the 14th channel 4 Press ENTER to confirm 5 The display shows D XX X stands for the DMX value of the selected channel 6 Press ENTER or...

Страница 11: ...th this function you can switch the lamp on or off via an external controller 1 Select ONLI by pressing UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enabl...

Страница 12: ...0 3 Press UP to change the selection 4 Press ENTER to save and then EXIT DN to exit Switch 16 bit 8 bit With this function you can switch MY575 from 16 bit to 8 bit resolution 1 Select 16BI by pressin...

Страница 13: ...n adjust the lamp via the Display Panel The shutter opens and the lamp can be adjusted In this mode MY575 will not react to any control signal 1 Select LADJ by pressing UP button 2 Press ENTER the dis...

Страница 14: ...mber of hours 3 Press ENTER or EXIT DN to exit Clear fixture time With this function you can clear the running time of MY575 1 Select CLMT by pressing UP button 2 Press ENTER the display shows ON or O...

Страница 15: ...ect the channel no you would like to edit by pressing UP 6 Press ENTER to enter editing for the selected channel MY575 reacts to your settings The display shows the DMX value of the edited channel Suc...

Страница 16: ...g DOWN 5 Press ENTER the display shows OFF 6 Press UP the display shows ON 7 Press ENTER the display shows SC02 You successfully downloaded the first scene 8 Adjust the Step time as described above un...

Страница 17: ...9 Electronic focus CHANNEL 10 strobe effect maximum 15 flashes per second or random strobe dimming and shutter close open control CHANNEL 11 Dimming effect 0 100 only be activated while CHANNEL 10 is...

Страница 18: ...en 10 19 Rot gobo 1 20 29 Rot gobo 2 30 39 Rot gobo 3 40 49 Rot gobo 4 50 59 Rot gobo 5 60 69 Rot gobo 6 70 89 Gobo 1 shake slow to fast 90 109 Gobo 2 shake slow to fast 110 129 Gobo 3 shake slow to f...

Страница 19: ...slow to fast 110 129 Gobo 3 shake slow to fast 130 149 Gobo 4 shake slow to fast 150 169 Gobo 5 shake slow to fast 170 189 Gobo 6 shake slow to fast 190 255Rot gobo wheel cont rotation slow to fast C...

Страница 20: ...200 207Macro 10 208 215Macro 11 216 223Macro 12 224 231Macro 13 232 239Macro 14 240 247Macro 15 248 255Macro 16 Channel 9 Focus 0 255 Continuous adjustment from far to near Channel 10 Shutter strobe...

Страница 21: ...ting slower 224 255Pulse from no frost to full frost starting slow and getting faster Channel 14 Color Wheel 2 0 15 Open white 16 31 Color 1 32 47 Color 2 48 63 Color 3 64 79 Color 4 80 95 3200K corre...

Страница 22: ...or message 01Er 02Er 05Er flash repeated for 5 times and then MY575 will generate a reset signal all the stepper reset If the error message remains after performing reset more than 3 times it will det...

Страница 23: ...tive or its driving IC on the main circuit card The head will not be located in the default position after the reset 08Er Prism wheel error This message will appear after the reset of MY575 and if the...

Страница 24: ...cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents Be particular to check the fans and their vents That is where dust and debris can accumulate Accumulation of du...

Страница 25: ...MY575 SPOT Other Elektralite Products include Also check out our website at www myelektralite com CP 3 Controller CP 10xt Controller CP 16 24 Controller...

Страница 26: ...MY575 SPOT CP 20xt Controller TurboFog Fog Machine...

Страница 27: ...MY575 SPOT Turbohazer Haze Machine...

Отзывы: