23
- MY575 SPOT
CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1) All screws, clamps etc. used to install
MY575
have to be tight and must not be corroded. Check them
regularly because, remember,
MY575 moves
and so it will have an effect on whatever you are using to hang
the fixture.
2) There must not be any deformations on
MY575’s
housing and internal parts. Also check the points where
MY575
is installed including such things as ceiling mounting points, truss, half couplers, c clamps, safety
cables and so on).
4) Mechanical moving parts must not show any traces of wearing and must rotate evenly.
5) The power input cable must not show any damage or material fatigue.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or
solvents. Be particular to check the fans and their vents. That is where dust and debris can accumulate.
Accumulation of dust here can have a devastating effect on
MY575
. You must remove it regularly. Failure to do
so will cause overheating inside
MY575.
Overheating causes premature failure of the lamp and other critical
components.
There are no serviceable parts inside
MY575
except for the lamp. Please refer to the
instructions under “Installation instructions”.
Should you need any spare parts, please order genuine parts from your local dealer.
TECHNICAL SPECIFICATIONS
Power supply
:
□
120VAC,60Hz;
Power consumption
: max. 800VI.
Lamp
: MSR 575/2
Motors : 14 micro motors
Packing dimensions
:29” x 23” x 25”
Net weight :
75 pounds
Please note, Elektralite is constantly improving their product range and we reserve the right to make changes
without prior notice.