background image

 -                                     MY575 SPOT 

Safety Instructions.

 

This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe 
operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in 
this user manual. 

MY575 

is a high voltage fixture. Be careful when dealing with high voltages.     

Please read this manual. If you do not read this manual and damages occur to MY575, then it could 
void the warranty.   

During shipping, 

MY575

 may have been exposed to high temperature changes or humidity changes. So, as a 

precaution, do not switch 

MY575

 on immediately. Condensation can damage 

MY575 

so leave 

MY575

 switched 

off until it has reached room temperature. 
The electric connection must carry out by a qualified person and it is absolutely essential that 

MY575

 be 

grounded

 
Always disconnect 

MY575 

from the power source, when the device is not in use or before cleaning it. Only 

unplug 

MY575

 from the power cord. Never pull out the plug out by pulling on the power cord. 

Take care, MY575 will heat up when it is turned on and it will be very hot to touch. 

 
Please keep 

MY575 

away from children and the general public. Please be intelligent and use common sense 

when operating 

MY575. 

 

General Guidelines.

 

MY575

 is a lighting fixture for professional use on stages, in clubs, theatres, etc. 

MY575 

should only be operated at 120 volts and only indoors. 

MY575 

should not be operated 24/7 (24 hours a day; 7 days a week). 

MY575 

needs operation breaks to 

ensure that it will work for a long time without problems. Please do not shake 

MY575 

and avoid using brute 

force when installing or operating it.   
 
When choosing the location to install 

MY575

, please make sure that it is not exposed to extreme heat, moisture 

or dust. The minimum distance between 

MY575 

and the illuminated surface must be more than 3 feet. 

 
Always mount 

MY575 

with an appropriate safety cable. If you use the quick lock cam to hang 

MY575

, please 

make sure the 4 quick lock fasteners are 

locked into position correctly. 

   
Operate 

MY575

 only when you are familiar with the features on the fixture. Do not permit operation by persons 

not qualified for operating it.   
All modifications to 

MY575 will invalidate the warranty. There are absolutely no exceptions.

 

 
If 

MY575 

is operated in any way different to the one described in this manual, 

MY575 

maybe damaged and the 

guarantee will be void.   

 

Содержание MY 575.3

Страница 1: ...MY 575 3 USER MANUAL V1 03...

Страница 2: ...r 0 15Hz or random strobe dimmer mechanical adjustable from 0 to 100 colors 2 color wheels color wheel 1 has 7 dichroic filters plus white with rainbow effect color wheel 2 4 dichroic filters plus whi...

Страница 3: ...ry hot to touch Please keep MY575 away from children and the general public Please be intelligent and use common sense when operating MY575 General Guidelines MY575 is a lighting fixture for professio...

Страница 4: ...A B C on the bottom of the housing holding the plate under which the lamp is located Carefully remove the metal plate 2 Carefully insert the lamp into the socket Please remember the lamp is polarized...

Страница 5: ...ing used Periodic safety inspections should be done of MY575 as the fixture does move If you do not have the qualifications and experience do not attempt the installation Improper installation can res...

Страница 6: ...ng the correct number on the display located on the base of MY575 You can set the same starting address for all fixtures or group of fixtures like all the MY575s in your plot or you can make different...

Страница 7: ...wn buttons to change the address 2 The default for the lamp striking is from the board channel 14 The fixture s lamp will not just start up when you turn on the fixture The main menu is accessed by pr...

Страница 8: ...n off ONLI ON OFF Lamp on off via controller 1 LAMP DELA D 00 D 59 D 15 Delay lamp on RPAN ON OFF Pan Reverse VER V1 0 V9 9 Software Version LODA ON OFF Restore Default factory setting REST ON OFF Res...

Страница 9: ...T DN to return to main menu Slave setting With this function you can define the device as slave 1 Select SLAV by pressing the UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select O...

Страница 10: ...el If you select D 14 the display will only show the DMX value of the 14th channel 4 Press ENTER to confirm 5 The display shows D XX X stands for the DMX value of the selected channel 6 Press ENTER or...

Страница 11: ...th this function you can switch the lamp on or off via an external controller 1 Select ONLI by pressing UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enabl...

Страница 12: ...0 3 Press UP to change the selection 4 Press ENTER to save and then EXIT DN to exit Switch 16 bit 8 bit With this function you can switch MY575 from 16 bit to 8 bit resolution 1 Select 16BI by pressin...

Страница 13: ...n adjust the lamp via the Display Panel The shutter opens and the lamp can be adjusted In this mode MY575 will not react to any control signal 1 Select LADJ by pressing UP button 2 Press ENTER the dis...

Страница 14: ...mber of hours 3 Press ENTER or EXIT DN to exit Clear fixture time With this function you can clear the running time of MY575 1 Select CLMT by pressing UP button 2 Press ENTER the display shows ON or O...

Страница 15: ...ect the channel no you would like to edit by pressing UP 6 Press ENTER to enter editing for the selected channel MY575 reacts to your settings The display shows the DMX value of the edited channel Suc...

Страница 16: ...g DOWN 5 Press ENTER the display shows OFF 6 Press UP the display shows ON 7 Press ENTER the display shows SC02 You successfully downloaded the first scene 8 Adjust the Step time as described above un...

Страница 17: ...9 Electronic focus CHANNEL 10 strobe effect maximum 15 flashes per second or random strobe dimming and shutter close open control CHANNEL 11 Dimming effect 0 100 only be activated while CHANNEL 10 is...

Страница 18: ...en 10 19 Rot gobo 1 20 29 Rot gobo 2 30 39 Rot gobo 3 40 49 Rot gobo 4 50 59 Rot gobo 5 60 69 Rot gobo 6 70 89 Gobo 1 shake slow to fast 90 109 Gobo 2 shake slow to fast 110 129 Gobo 3 shake slow to f...

Страница 19: ...slow to fast 110 129 Gobo 3 shake slow to fast 130 149 Gobo 4 shake slow to fast 150 169 Gobo 5 shake slow to fast 170 189 Gobo 6 shake slow to fast 190 255Rot gobo wheel cont rotation slow to fast C...

Страница 20: ...200 207Macro 10 208 215Macro 11 216 223Macro 12 224 231Macro 13 232 239Macro 14 240 247Macro 15 248 255Macro 16 Channel 9 Focus 0 255 Continuous adjustment from far to near Channel 10 Shutter strobe...

Страница 21: ...ting slower 224 255Pulse from no frost to full frost starting slow and getting faster Channel 14 Color Wheel 2 0 15 Open white 16 31 Color 1 32 47 Color 2 48 63 Color 3 64 79 Color 4 80 95 3200K corre...

Страница 22: ...or message 01Er 02Er 05Er flash repeated for 5 times and then MY575 will generate a reset signal all the stepper reset If the error message remains after performing reset more than 3 times it will det...

Страница 23: ...tive or its driving IC on the main circuit card The head will not be located in the default position after the reset 08Er Prism wheel error This message will appear after the reset of MY575 and if the...

Страница 24: ...cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents Be particular to check the fans and their vents That is where dust and debris can accumulate Accumulation of du...

Страница 25: ...MY575 SPOT Other Elektralite Products include Also check out our website at www myelektralite com CP 3 Controller CP 10xt Controller CP 16 24 Controller...

Страница 26: ...MY575 SPOT CP 20xt Controller TurboFog Fog Machine...

Страница 27: ...MY575 SPOT Turbohazer Haze Machine...