Introduction
The PC Settings are configured by selecting Configure > PC Settings from the
Menu Bar at the top of the screen. Refer to Figure 9–2. Default values are preset
at the factory.
Software Screen
Figure 9–2
Comm Port
There is one (1) physical connection and four (4) software selected ports. Default
is 1.
Comm Time Out
Comm Time Out is the number of times communication is attempted before an
error occurs. Default is 15,000.
Comm Update Timer
Comm Update Timer is the time between data exchanges between the PLC and
the PC. Default is 500 ms.
Graphic Update Timer
The refresh rate in milliseconds for the video display is determined by the value
entered in Graphic Update Timer. Sometimes a slightly higher or lower value
improves the appearance of the display when industrial noise interferes with an
optimal display.
Log Alarms
Records any alarms in the alarm history file. If this is not selected, the alarms are
not recorded in the log history.