B R A V O ™ S Y S T E M O P E R A T I O N
Starting and Stopping the Bravo™ System
4-56
Bravo™ 8105 Programming and Operations Guide
Rev. 2
4
Starting and Stopping the Bravo™ System
Introduction
The Bravo™ System has an AUTO Start feature that starts the components in a
controlled manner. Alternately, the components may be started individually in
Manual Mode. When in Auto Mode, the Bravo™ also has an AUTO Stop feature
that shuts down the machine in a predetermined sequence.
AUTO Mode
In the Process Screen (either Graphic or Tabular) ensure that "AUTO" is chosen in
the Machine Mode field. Press the Start button to initiate a controlled Power Up
of the machine components. Alternately, press Function Key F2.
The machine is in AUTO Mode if the label near “Machine Mode” displays
“Automatic”. Additionally a button displays “Go to Manual” near the same label.
To AUTO Start the Bravo™ System, click on the Start button associated with
Machine Mode, or press Function Key F2.
To AUTO Stop the Bravo™ System, click on the Stop button or press Function
Key F3.
Note that the Machine Mode parameter is saved to each recipe. If a new recipe is
loaded that does not have AUTO Mode configured, the machine converts to
Manual Mode until it is changed in one of the Process Screens or until the Recipe
is changed and re–loaded.
Manual Mode
To operate the Bravo™ System in Manual Mode, ensure that “Manual” is chosen
in the Machine Mode field. Press the On/Off button of each component to start
the machine components. The Blowers turn On automatically if a Heater is
started.
The machine is in Manual Mode if the label near “Machine Mode” displays
“Manual”. Additionally a button displays “Go to Auto” near the same label.
To Stop the Bravo when it is in Manual Mode, each component is turned off
individually.
ATTENTION
Note that regardless of Machine Mode, the Blowers operate until the internal
temperature of the heated chamber falls below a user-defined parameter, defined
in Configure > Misc Params. The default is 95 C (203 F).
Содержание Bravo 8105
Страница 2: ...Bravo 8105 Programming and Operations Guide ...
Страница 14: ...T A B L E O F C O NT E N T S xiv Bravo Programming and Operations Guide Rev 2 ...
Страница 42: ...T E C H N IC A L D A T A Electrical Information 2 28 Bravo 8105 Programming and Operations Guide Rev 2 2 ...
Страница 90: ...A LA R M S Alarm History 7 76 Bravo 8105 Programming and Operations Guide Rev 2 7 ...
Страница 126: ...M A IN T D IA G S C R E E N S PLC Status 10 112 Bravo 8105 Programming and Operations Guide Rev 2 10 ...