Содержание Penta

Страница 1: ......

Страница 2: ...de to Programming 17 4 3 Programming Parameters 18 4 4 Periodic Test Timer Reset 23 Appendix A Hexadecimal Conversion Chart 24 Appendix B Glossary of Terms 25 Index 28 Introduction This manual is designed to help you with the installation process for the Penta control panel We strongly urge you to read through this manual in its entirety before beginning the installation process so that you can be...

Страница 3: ...nta offers five zone response types for customized programming to suit a wide range of installations Each zone can be programmed to activate a siren bell when tripped or to generate a silent alarm where only a message is sent to the central station The following is a summary of the operational characteristics for each zone response type Perimeter Zone Perimeter zones instantly generate an alarm wh...

Страница 4: ...umber The Penta offers a number of communication options and supports either pulse or DTMF dialing Central Station Communication The Penta s on board dialer uses the following protocols for central station communication Contact ID 20pps 4 2 no parity 10pps 3 1 no parity Follow me Using the Follow me feature the panel informs the user that an event has occurred by dialing the user s telephone numbe...

Страница 5: ...n is restricted Answering Machine Override Answering machine override enables the control panel to distinguish between regular incoming calls and a communication attempt by the RP remote programmer software An RP call is identified by the control panel as a sequence of two calls within a 30 second time window 1 The control panel does not answer the first incoming call 2 The control panel opens a 3...

Страница 6: ...3104 LED keypad 1 2 2KΩ W resistors 5 6 x screws 4 Mounting studs 4 PCB support 1 Installation manual 1 User manual 1 Optional Parts Additional 3104 LED keypad 3601 voice message module Remote Programmer up downloading software 3911 remote programming device 230 15VAC transformer Cabinet tamper protection switch ...

Страница 7: ...rated 13 5 14 0V Battery Operated 12V Nominal AC Transformer 50 60Hz 15Vac 22 30VA Do not connect to a switch controlled receptacle LED Keypad BELL SIREN OUTPUT 600mA max 1 2 3 4 5 6 7 8 9 10 11 12 14 15 PGM 13 16 Telephone Line Connections Tamper Zone B L A C K R E D 12V 3 2Ah BATTERY Replace the battery every 3 5 years The maximum charging current is 350mA JPD Jumper for factory default restore ...

Страница 8: ...rated at 600mA max Bell Supervision USA hardware only The bell connections must be terminated by a 2 2K W resistor as shown in Figure 2 1 PGM Programmable Output Terminal 9 The PGM output switches to ground when activated enabling the connection of additional system status indicators Connect the PGM output as shown in the Figure 2 2 Tamper Zone Keyswitch Connections Terminal 10 Connect a tamper sw...

Страница 9: ...In the event of problems you should contact your equipment supplier in the first instance 2 4 Mounting the Keypad 1 2 3 4 AB Figure 2 4 3104 LED Keypad cover removed Up to 3 LED keypads can be connected to the Penta control panel To mount the keypad 1 Separate the front and back cover of the keypad by pressing the locking tabs situated at the bottom of the keypad with a small flathead screwdriver ...

Страница 10: ...ct Electronics Line s Technical Support Department The Penta control panel is supplied with a default program that includes typical programming data which means that minimum programming is required for typical installations To turn on the system 1 Install the JPD jumper located at the top of the control panel board 2 Reapply power and wait for 10 seconds the keypad beeps to indicate the end of the...

Страница 11: ... information LED Display 1 4 LEDs 1 4 are used to display zone status The corresponding LED lights up if a zone is open If a zone is bypassed the corresponding LED blinks READY The Ready LED lights up to indicate that there are no open zones or tamper conditions and the system is ready to be armed SYSTEM The System LED blinks to indicate that new events have been recorded in one of the logs and wh...

Страница 12: ...ser performed the operation To arm the system 1 Check that all zones are closed the Ready LED lights up to indicate that the system is ready to be armed 2 Enter a valid user code the keypad beeps until the end of the exit delay Forced Arming Forced arming enables the user to arm the system with open zones Electronics Line recommends waiting until all of the zones are secured and the system can be ...

Страница 13: ... turned off If the correct code is not entered by the end of the delay time an alarm will be generated Keyswitch Arming Disarming The system can be armed and disarmed using an ON OFF keyswitch The keyswitch has two operation modes 1 Latching closing the keyswitch arms the system opening disarms the system 2 Momentary opening and closing the keyswitch either arms or disarms the system 3 5 Distress ...

Страница 14: ...ing 5 Enter the next code to be changed or press to exit Note If the new code is identical to an existing user code an error tone will be sounded and the new code will not be accepted To erase a user code 1 Press Q 5 2 Enter User Code 1 3 Enter the number of the code to be erased 1 4 the requested zone LED flashes 4 Enter Q Q Q Q the LED stops flashing and the code is erased 5 Enter the next code ...

Страница 15: ...n recorded in either event log the System LED flashes until the relevant event log has been viewed In the event that a trouble condition still exists the System LED continues to flash until the condition has been remedied Emergency Trouble Event Log Zone tamper keypad trouble or any of the three distress key alarms are registered in the Emergency Trouble event log To view the Emergency Trouble eve...

Страница 16: ...Test mode press This mode is automatically terminated after 4 minutes Note The Tamper Zone always generates an alarm if opened even if the system is in Walk Test mode Stop Communications To cancel the transmission of all unsent messages 1 Press ENTER 1 2 Enter User Code 1 all communication buffers are cleared and all communications stop immediately Zone Chime On Off The keypad can be set to chime ...

Страница 17: ...installer code is 1234 the Armed LED lights up and the System LED flashes 4 Enter the two digit parameter number to be programmed the Ready LED lights up and the Armed LED turns off 5 Enter a new value or press to cancel if the value has been successfully changed the keypad sounds an acknowledge tone to confirm and the Ready LED turns off 6 Press to exit programming mode Note The default Installer...

Страница 18: ...he number of communication rounds is defined in the first digit of this address The number of dialing attempts in each round is defined in the second digit Note To Disable Communications enter 00 at this address First Digit Communication Rounds Enter a value between 1 F F Unlimited rounds until communication is established Second Digit Dialing Attempts Enter a value between 1 F Address 01 Miscella...

Страница 19: ... 03 Zone 1 Definition One of six response types can be assigned to zone 1 Each zone type can be programmed as Silent or Audible A Silent zone will not activate a siren or bell when the zone is tripped 00 Perimeter zone with delay Silent 10 Perimeter zone with delay Audible 01 Perimeter zone Silent 11 Perimeter zone Audible 02 Conditional zone Silent 12 Conditional zone Audible 03 Interior zone Sil...

Страница 20: ...e conditions When the PGM output is activated terminal 9 switches to ground Choose the PGM output setting from the following table Value Name Activated By Deactivated By 00 PGM Disabled 01 Arm Disarm System Armed System Disarmed 02 Entry Exit Entry Exit Tone Follower Entry Exit Tone Follower 04 Communication System in Communication End of Communication 08 AC Loss AC Loss AC Restore 10 Bell Followe...

Страница 21: ...Code 2 Address 29 System Armed User Code 3 Address 30 System Armed User Code 4 Address 31 System Disarmed User Code 1 Address 32 System Disarmed User Code 2 Address 33 System Disarmed User Code 3 Address 34 System Disarmed User Code 4 Address 35 System Disarmed Duress Code Address 36 Low Battery Address 37 AC Loss Address 38 Bell Trouble Address 39 Keypad Trouble Address 40 Low Battery Restore Add...

Страница 22: ...cation round the backup telephone number is dialed The backup telephone number is programmed in the same way as the primary telephone number address 54 Address 56 RP Callback Telephone Number Remote programming communication can be established using two methods passcode and callback see address 02 second digit If RP callback is selected the panel receives a call from the remote programmer hangs up...

Страница 23: ...hours The first transmission of this code is sent 12 hours after power is applied to the control panel If a different time is required the control panel can be programmed to send the first periodic test message 24 hours after the periodic test timer is reset To reset the periodic test timer 1 Press Q 7 to enter programming mode 2 Enter the Installer Code the Armed LED lights up and the System LED ...

Страница 24: ... 76 4C 108 6C 140 8C 172 AC 204 CC 236 EC 13 0D 45 2D 77 4D 109 6D 141 8D 173 AD 205 CD 237 ED 14 0E 46 2E 78 4E 110 6E 142 8E 174 AE 206 CE 238 EE 15 0F 47 2F 79 4F 111 6F 143 8F 175 AF 207 CF 239 EF 16 10 48 30 80 50 112 70 144 90 176 B0 208 D0 240 F0 17 11 49 31 81 51 113 71 145 91 177 B1 209 D1 241 F1 18 12 50 32 82 52 114 72 146 92 178 B2 210 D2 242 F2 19 13 51 33 83 53 115 73 147 93 179 B3 2...

Страница 25: ... audible zone generates an alarm Bell LED Test An operation that checks if the bell siren and keypad LEDs are functional The bell test sounds the bell and lights all the LEDs on the keypad for a period of two seconds Bypassed Zone A zone which is ignored by the system No alarm is generated from a bypassed zone even when the system is armed C Callback A toll saver feature which cuts the cost of rem...

Страница 26: ... connected to the tamper zone for arming and disarming the system by the turn of a key L Latching One of the two keyswitch function modes A latching keyswitch toggles the system to arm or disarm by one turn of the key On or Off Arm Disarm Log See Event Log Low Battery Condition brought about if the voltage supplied to the backup battery deteriorates to approximately 10 5V or less M Magnetic Contac...

Страница 27: ... alarm that does not activate the bell siren when generated Stay Arming Arming the perimeter of the system while allowing free movement in the interior zones Stop Communications An operation that clears all communication buffers and stops all communications immediately T Tamper Zone The fifth zone which can be connected to a tamper switch protecting the control panel by generating an alarm when th...

Страница 28: ...odes 20 Event Logs 15 Exit Delay 20 F Key 13 Fast Loop Perimeter Zone 4 Fire Key 13 Follow me 4 General Description 4 5 Forced Arming 12 Fuse Replacement 6 Handshake 19 Hexadecimal Data 17 Conversion Chart 24 Immediate Arming 13 Installation 6 Installer Code 14 17 23 Interior Zone 4 13 19 Introduction 2 JPD Jumper 10 Keypad Address Definition 9 Backlight On Off 16 Command Codes 12 Configuration 18...

Страница 29: ... 16 System LED 11 Tamper Zone 18 Telephone Communication 4 Follow me 4 5 RP Communication 5 Telephone Line Connections 9 Telephone Numbers 4 22 Telephone Options 19 Terminal Connections 8 Test Bell 16 Walk 16 Trouble Indication 20 Turning on the System 10 Unbypassing Zones 15 User Codes 3 14 Erasing 14 Programming 14 Walk Test 16 Wiring Diagram 7 Zone Chime 16 Zones 3 24hr 4 19 Audible 19 Bypassin...

Страница 30: ...ontains the entire warranty Additionally this warranty is in lieu of all other obligations or liabilities on the part of E L It is the sole warranty and any prior agreements or representations whether oral or written are either merged herein or are expressly canceled E L neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any othe...

Страница 31: ...ndshake 1400Hz Handshake RP Access Type Passcode RP Access Enable RP Access ____ ____ ____ ____ ____ 0 2 1 0 1 Protocol Contact ID ZONE DEFINITIONS 03 06 Default value for all zones 00 Perimeter zone with delay silent TIMERS PGM OUTPUT FUNCTION 07 __ __h Entry Delay 15 Sec 10 __ __ PGM Disabled 08 __ __h Exit Delay 60 Sec 09 __ __h Bell Cut Off 5 Min EVENT CODES 11 53 Default value for all event c...

Страница 32: ...pps 3 1 no parity Fourth Digit Handshake 0 1400Hz Handshake 1 2300Hz Handshake Second Digit RP Access Type 0 Passcode 1 Callback Third Digit RP Access 0 Disable RP Access 1 Enable RP Access ZONE DEFINITIONS 03 __ __ Zone 1 04 __ __ Zone 2 05 __ __ Zone 3 06 __ __ Zone 4 TIMERS 07 __ __h Entry Delay 1 255 Sec PGM OUTPUT FUNCTION 08 __ __h Exit Delay 1 255 Sec 10 __ __ 09 __ __ Bell Cut Off 1 5 Min ...

Страница 33: ...ss 36 __ __ Low Battery 37 __ __ AC Loss 38 __ __ Bell Trouble 39 __ __ Keypad Trouble 40 __ __ Low Battery Restore 41 __ __ AC Loss Restore 42 __ __ Bell Trouble Restore 43 __ __ Keypad Trouble Restore 44 __ __ Bell Cancel 45 __ __ Periodic Test 46 __ __ Bypass Zone 1 47 __ __ Bypass Zone 2 48 __ __ Bypass Zone 3 49 __ __ Bypass Zone 4 50 __ __ Unbypass Zone 1 51 __ __ Unbypass Zone 2 52 __ __ Un...