-13-
Stay Arming
This feature only arms perimeter zones – i.e. Perimeter, Perimeter with Delay and Fast
Loop Perimeter zones. This allows the user to stay within the protected area while the
system is armed.
To “Stay” arm the system:
1. Check that all zones are closed apart from the interior zones; the Ready LED lights
up to indicate that the system is ready to be armed.
2. Press
Q
,
9
.
3. Enter a valid user code; the keypad beeps until the end of the exit delay.
Immediate Arming
The system can be operated without an entry/exit delay. Pressing
Q
during the exit
delay or when the system is armed cancels both the exit and entry delay times.
Note: It is not recommended to use this feature with an external keypad.
Disarming
The Penta can be disarmed by entering a valid user code during the entry delay. If an
error is made entering the code, press ‘#’ and enter the code again. When the code is
accepted the Armed LED and the pulsed delay tone are turned off. If the correct code is
not entered by the end of the delay time, an alarm will be generated.
Keyswitch Arming/Disarming
The system can be armed and disarmed using an ON/OFF keyswitch. The keyswitch
has two operation modes.
1. Latching - closing the keyswitch arms the system, opening disarms the system.
2. Momentary - opening and closing the keyswitch either arms or disarms the system.
3.5: Distress Keys
In the case of an emergency, 3 types of alarms can be generated by pressing and
holding down the desired distress key for more than 2 seconds. These alarms will send
the relevant distress codes to the central station. The distress keys are as follows:
F
E
P
FIRE:
Sounds the fire bell, sends the ‘Fire’ event code to the central
station (address 17) and registers in the Emergency/Trouble event log.
EMERGENCY:
Sends the ‘Emergency’ event code to the central station
(address 18), sounds the siren (if programmed at address 01) and
registers in the Emergency/Trouble event log.
POLICE:
Sends the ‘Police’ event code to the central station (address 16),
sounds the siren (if programmed at address 01) and registers in
the Emergency/Trouble event log.
Содержание Penta
Страница 1: ......