-22-
Address 43: Keypad Trouble Restore
Address 44: Bell Cancel
Address 45: Periodic Test
Address 46: Bypass Zone 1
Address 47: Bypass Zone 2
Address 48: Bypass Zone 3
Address 49: Bypass Zone 4
Address 50: Unbypass Zone 1
Address 51: Unbypass Zone 2
Address 52: Unbypass Zone 3
Address 53: Unbypass Zone 4
Telephone numbers
Address 54: Primary Telephone Number
The primary telephone number is the first number that is dialed when an event occurs.
A maximum of 16 digits can be entered at this address. To add a two-second pause,
enter B (
Q
, 1). To switch from pulse to DTMF dialing enter E (
Q
, 4). These hexadecimal
digits, B and E, are included in the 16 digit total. Press ENTER after the last digit of the
telephone number has been programmed.
Address 55: Backup Telephone Number
If the panel fails to communicate with the primary number within a communication
round, the backup telephone number is dialed. The backup telephone number is
programmed in the same way as the primary telephone number (address 54).
Address 56: RP Callback Telephone Number
Remote programming communication can be established using two methods,
passcode and callback (see address 02, second digit). If RP callback is selected the
panel receives a call from the remote programmer, hangs up and calls back using the
telephone number programmed at this address. The RP callback telephone number is
programmed in the same way as the primary telephone number (address 54).
Note: To disable a telephone number, enter the appropriate address and press
ENTER. It is not possible to program a backup number unless a primary number
has been programmed.
Address 57: RP Access Code
This 4-digit code grants access to the remote programmer.
Note: Do not enter Hex digits.
Address 58: Account Number
When an event code is sent, the central station receives an account number to identify
the customer. Enter a 4-digit account number at this address.
Содержание Penta