40
10.11 Heating
element
When replacing the heating element, please refer to the code shown in the list of
spare parts relating to the appliance.
It is strictly forbidden to tamper with the heating element in
any way!!!
(e.g. changing the NTC probe, etc...)
10.11.1 General characteristics
1. NTC
probe
2. Heating
element
The heating element of the washing water is armoured, i.e. it is inserted in sealed tubular stainless steel
casing.
It is powered by two relays (K1, K2) situated in the circuit board. It is fitted with two thermal fuses which trip if
the temperature of the heating element exceeds the values for which they were calibrated.
(In the event of a fault an alarm will be displayed - see table of alarms).
1. Main
circuit
board
11. Heating element
1
2
Содержание WE170P
Страница 1: ...Service manual Washer extractor WE170V WE170P 438 9167 20 EN 2015 03 03 Original instructions ...
Страница 2: ......
Страница 81: ......
Страница 82: ......
Страница 83: ......
Страница 84: ......
Страница 85: ...www electrolux com myPro ...