56
11.1 Alarm codes for appliance with external liquid supply system
Alarm
code
Alarm description
Fault condition
Possible fault
Machine
action/status
Reset key
E9A
DET_DOSING_ABS_AL
External liquid supply system configured but communication failure
(before payment).
Wiring defective
External liquid supply system defective
MB defective
No power supply to sat
Cycle blocked
OFF/ON
EF9
DET_DOSING_COM_AL
External liquid supply system configured but communication failure
(after payment).
Wiring defective
External liquid supply system defective
MB defective
No or wrong power supply to sat
No actions
OFF/ON
11.2 Detailed description of alarm codes
11.2.1 E9A - External liquid supply system configured but communication failure (before payment)
The user has not yet paid and there are communication problems in between External liquid supply system board and Motherboard.
Problems could be due to Hardware (problems on connectors for example disconnection, on satellite or mother board), due to disturbs (burst on wiring) or satellite
unplugged from power supply.
The alarm appears after 5 seconds of missing communication after which the communication is interrupted for 35 seconds. Then the Motherboard retries to restore the
connection and, if the problem remains, disconnects again.
This alarm is displayed on the user interface using the format “E” + “9”(alarm family digit) + “0”.
When the alarm is set the machine is blocked. To clear the alarm is necessary to switch off the machine.
11.2.2 EF9 — External liquid supply system configured but communication failure (after payment)
The user has already paid and there are communication problems in between External liquid supply system board and Motherboard.
Problems could be due to Hardware (problems on connectors for example disconnection, on satellite or mother board), due to disturbs (burst on wiring) or satellite
unplugged from power supply.
The alarm appears after 5 seconds of missing communication after which the communication is interrupted for 35 seconds. Then the Motherboard retries to restore the
connection and, if the problem remains, disconnects again.
The alarm is not displayed.
No action is executed when alarm is detected. To clear the alarm is necessary to switch off the machine.