Steam and condensate connections: indirect steam heating
Steam connection
The customer must install a line purge, a manually closing valve with handwheel lockable in off
position (do not use a 1/4 turn valve) and a fi lter on the supply side of the washer-extractor.
Hereunder values apply to the steam pressure.
Recommended pressure : 300 at 600 kPa (3 at 6 kg/cm²) (43.5 at 87 psi)
Limiting of values :
mini. 100 kPa (1 kg/cm²) (14.5 psi)
maxi. 600 kPa (6 kg/cm²) (87psi)
Connection size : DN 15 (½" BSP).
Condensate connection
The customer must install a steam trap with fl oat closed with an incondensibles drainage
device, a by-pass, a non-return valve and a manual closing valve lockable in off position (do not
use a 1/4 turn valve).
Connection size : DN 15 (½" BSP).
Connect the steam installation on the top of
the machine (see example sketch).
A
Washer-extractor
B
Line trap (provided by customer)
C
Return of condensates
D
Manual stop wheel valve (provided
by customer)
E
Steam
fi
lter
(provided
by
customer)
F
Steam trap (provided)
H
Non-return valve (provided
by customer)
M
Pressure gauge (provided
by customer)
N
Thermal insulation for the pipework
(provided by customer)
P
Steam electrovalve (provided)
S
Safety valve (provided by customer)
V
Steam
inlet
•
•
9. Installation
Содержание Washer-extractors WS4250H
Страница 2: ... ...
Страница 41: ...1009 7 9 Notice Date Page 01201138 INSTRUCTION HANDBOOK 9 Installation This page ist left blank on purpose ...
Страница 67: ...0807 33 9 Notice Date Page 01201138 INSTRUCTION HANDBOOK 9 Installation This page ist left blank on purpose ...
Страница 145: ...0107 76 11 Notice Date Page 01201138 INSTRUCTION HANDBOOK This page ist left blank on purpose 11 Machine operation ...
Страница 167: ... ...
Страница 168: ...www electrolux com laundrysystems Share more of our thinking at www electrolux com ...