487 18 39 01 - 300/500/750 - GB
Installation - gas heating
Gas type
Gas pressure
Ø
Inlet
Nozzle
1
MJ/m3
mbar
mbar
mm
LPG
126.4
30
30
2.2
GNH
37.4
18
10.5
3.8
GNL
33.6
18
15.2
3.8
LPG
126.4
30
30
3.2
GNH
37.4
18
8
5.6
GNL
33.6
18
8
6.2
LPG
126.4
30
30
3.8
GNH
37.4
18
9.5
6.5
GNL
33.6
18
14
6.5
Nozzle pressure
(Measuring branch)
2
Tumble
type
Heat effect
500/50
750/75
650
40
57
kW
300/30
21
Tables of pressure and adjustments only for english speaking countries
except: Great Britan, Eire, Australia and New Zealand.
Upper calorific
value
Gas installation
Gas type
Gas pressure
Ø
Inlet
Nozzle
1
MJ/m3
mbar
mbar
mm
LPG
125.81
28/37
28/37
2.2
GNH
37.78
20
10.5
3.8
LPG
125.81
28/37
28/37
3.2
GNH
37.78
20
8
5.6
LPG
125.81
28/37
28/37
3.8
GNH
37.78
20
9.5
6.5
Nozzle pressure
(Measuring branch)
2
Tumble
type
Heat effect
500/50
750/75
650
40
57
kW
300/30
21
Tables of pressure and adjustments
only for: Great Britan and Eire
Upper calorific
value
44
Содержание TT300
Страница 1: ...Operating and installation manual TT300 TT500 TT750 487 1839 51 01 99 31 ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 18: ...Instructions for use 18 487 18 39 01 300 500 750 GB ...
Страница 26: ...General installation 487 18 39 01 300 500 750 GB 26 ...
Страница 38: ...Installation electric steam and gas heating 487 18 39 01 300 500 750 GB 38 ...
Страница 46: ...Installation electric steam and gas heating 487 18 39 01 300 500 750 GB 44 2 ...