84
Service Manual
13:11 UNLOADING DOOR NOT LOCKED
This error code will be shown if the control system has not detected the input UNLOADING DOOR LOCKED to be ac-
tive within a certain time after closing the unloading door.
Possible causes:
This can be caused by a mechanical problem preventing door lock to lock, defective door lock, loose cable connec-
tion to door lock, broken cables to door lock or mechanical problem with emergency opening of the door.
Recommended actions:
1. Check door lock functionality in service program, by activating door lock and then by monitoring input status
under Check inputs and outputs.
2. Check electrical connections by reading inputs at the same time as cables carefully moved/pulled.
3. Carefully knock on the door lock unit to locate intermittent errors.
13:12 LOADING DOOR NOT LOCKED
This error code will be shown if the control system detects that the input LOADING DOOR LOCKED has been deacti-
vated during an on-going program.
Possible causes:
This can be caused by a mechanical problem preventing door lock to lock, defective door lock, loose cable connec-
tion to door lock, broken cables to door lock or mechanical problem with emergency opening of the door.
Recommended actions:
1. Check door lock functionality in service program, by activating door lock and then by monitoring input status
under Check inputs and outputs.
2. Check electrical connections by reading inputs at the same time as cables carefully moved/pulled.
3. Carefully knock on the door lock unit to locate intermittent errors.
13:13 UNLOADING DOOR NOT LOCKED
This error code will be shown if the control system detects that the input UNLOADING DOOR LOCKED has been de-
activated during an on-going program.
Possible causes:
This can be caused by a mechanical problem preventing door lock to lock, defective door lock, loose cable connec-
tion to door lock, broken cables to door lock or mechanical problem with emergency opening of the door.
Recommended actions:
1. Check door lock functionality in service program, by activating door lock and then by monitoring input status
under Check inputs and outputs.
2. Check electrical connections by reading inputs at the same time as cables carefully moved/pulled.
3. Carefully knock on the door lock unit to locate intermittent errors.
13:14 INNER DRUM DOOR NOT CLOSED
This error code will be shown if the control system detects that the input INNER DOOR OPEN is activated during pro-
gram start or becomes activate when drum is ordered to drive/drum is rotating.
Recommended actions:
1. Check functionality of INNER DOOR OPEN SENSOR (DP7), i.e inactive when door is closed and active when
door is open.
2. Check door lock functionality in service program, by activating door lock and then by monitoring input status
under Check inputs and outputs.
13:15 COMPRESSED AIR IS MISSING
Machine indicates that compressed air is missing.
This error code will be shown if the control system detects that the input COMPRESSED AIR PRESENT is not
activated.
Recommended actions:
1. Check compressed air pressure to machine, valves is open, compressor on etc.
2. Check that input COMPRESSED AIR PRESENT activates when compressed air is present.
Содержание T5190LE
Страница 1: ...Service Manual Tumble dryer T5190LE Type N1190 Original instructions 438 9167 00 EN 2017 02 09 ...
Страница 2: ......
Страница 30: ...30 Service Manual Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Страница 35: ...Service Manual 35 Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Страница 40: ...40 Service Manual Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Страница 45: ...Service Manual 45 Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Страница 117: ......