20
Service Manual
Air circulation
A
Warm moist air
B
Cold air
C
Hot dry air
Heat pump
1
Compressor
2
Condenser
3
Evaporation unit
4
Heat exchanger
5
Solenoid valve
6
High pressostat
7
Low pressostat
8
Check valve
9
Drying filter
10
Expansion valve
11
Pressure operating water control valve
12
Fan
Refrigerant
a
Vapour, high pressure
b
Liquid, high pressure
c
Liquid, low pressure
d
Vapour, low pressure
9.4
Separating the units
If needed, it is possible to separate the tumble dryer from the heat pump unit:
• Disconnect the power to the machine.
• Disconnect the water and drain hoses.
• Demount the tumble dryer by unscrewing the screws on each side.
• Open the door and demount the screws on top of the the heat pump unit door.
• Open the heat pump unit door and disconnect the cable.
• Carefully lift off the tumble dryer from the heat pump unit.
fig.8006