13.3 Description of error codes and causes
MAIN COMMON
10:1 INTERNAL ERROR CPU TACHO
Tacho input on CPU delivers values that is out of range.
Recommended actions:
1. Run motor on highest possible speed in service mode. Check input value for RPM speed.
2. Replace defective component.
10:11 REAL TIME CLOCK OUT OF ORDER
The real time clock is used by the control system for delayed start, measuring time, power failure, error codes, etc.
Upon power on, the communication with the internal real time clock in the control system is established. In case this
fails, this error occurs
Recommended actions:
1. Power off the machine for 1 minute and try again.
10:13 INITIALIZATION FAILED
The error code is shown if the hardware initialization has failed to initialize within 15 seconds after power on.
Recommended actions:
1. Press the control knob/start button to retry.
2. Upload a new software that matches the machine configuration and try again.
10:15 MACHINE STOP
This message is shown if input for
MACHINE STOP
is activated.
This is not an error code but is handled in the same way.
Recommended actions:
1. Reset the Machine Stop Button.
2. Press the control knob to confirm machine stop. Machine will revert to Idle mode.
10:16 EMERGENCY STOP
This message is shown if input for
EMERGENCY STOP
is activated. This is not an error code but is handled in the same
way.
Recommended actions:
1. Reset the Emergency Stop Button.
2. Press the control knob to confirm emergency stop. Machine will revert to Idle mode.
Содержание T5190LE
Страница 1: ...Service Manual Tumble dryer T5190LE Type N1190 Original instructions 438 9167 00 EN 2017 02 09 ...
Страница 2: ......
Страница 30: ...30 Service Manual Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Страница 35: ...Service Manual 35 Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Страница 40: ...40 Service Manual Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Страница 45: ...Service Manual 45 Demount the control panel fig 7967A Demount the supporting rail fig 8044 ...
Страница 117: ......