9.2 Control panel (standard version)
9.2.1 Control panel – versions for “soft” cabinet
a. Remove the work-top
b. Extract the detergent drawer (8)
c. Remove the screws that secure the control panel to the control panel
support (9)
d. For models with knobs external to the control panel: release the knob
cover by pressing the hole gently with a small screwdriver and turning
the knob cover counter-clockwise (10)
e. Remove the screws which secure the control panel to the cross-
member and release the anchor tabs from the support (12)
f. Release the control panel from the lower right-hand guide and
remove. To facilitate its release, unscrew the screw which secures it
to the cabinet and lift the control panel support slightly (13 or 14).
g. Remove the pilot lamp from its housing in the control panel and (for
electronic models) disconnect the wiring connectors from the PCB.
When re-assembling
: Ensure that the knobs/flanges are positioned
correctly!
9.2.2 Control panel – versions for “square” cabinets
a. Remove the work-top
b. Extract the detergent drawer (8)
c. Remove the screws which secure the control panel to the control
panel support (9)
d. For models on which the knobs are external to the control panel:
release the knob cover by pressing the hole gently with a small
screwdriver and turning the knob cover counter-clockwise (10-11)
e. Remove the front-mounted screws which secure the control panel
support to the cabinet (13 or 14) and, if present, those that secure the
control panel (12).
f. If present, remove the internal screw that secures the control panel to
the support.
g. Release the tabs which anchor the control panel to the support (15-
16) and remove the control panel. To facilitate this operation, lift the
support to release the lower anchor tabs on the control panel (17).
h. Remove the pilot lamp from its housing in the control panel and (for
electronic models) disconnect the wiring connectors from the PCB.
When re-assembling
: Ensure that the knobs/flanges are positioned
correctly!
10
8
9
12
14
13
15
16
17