![Electrolux P6000 (Nexus) Series Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/electrolux/p6000-nexus-series/p6000-nexus-series_service-manual_2385422076.webp)
SOI/DT 2002-05 eb
76
599 35 23-17
8.10.2 Reversal of direction of rotation during washing
The windings are designed to provide rotation in both directions, depending on the way in which the
capacitor is connected. Each functions alternately as a primary winding and start-up winding. When reverse
rotation is required, the switching contact of the timer reverses the connection of the capacitor between the
two windings, thus reversing the direction of rotation.
Motor stopped
Clockwise rotation
Counter-clockwise rotation
8.10.3 Electrical symbols
Motor Capacitor
8.10.4 Circuit diagrams
Motor with traditional connection
Motor with suppressor connection
A
-
B
Low-speed windings
C
- Common low-speed winding
D
- High-speed running windings
E
- High-speed running winding
P
- Overload cut-out