![Electrolux P6000 (Nexus) Series Скачать руководство пользователя страница 111](http://html.mh-extra.com/html/electrolux/p6000-nexus-series/p6000-nexus-series_service-manual_2385422111.webp)
SOI/DT 2002-05 eb
111
599 35 23-17
9.10.4 Drain pump - models with Neat cabinet (Jetsy- IZ)
a. Lay the appliance face-down, remove the screws which secure the filter body and remove the filter from
the base (70)
b. Detach the drain hose from the pump.
c. Press down the two anchor tabs and detach the pump from the filter body (71).
d. Detach the wiring connector.
When re-assembling, ensure that the OR seal is fitted to the pump. To facilitate insertion, lubricate with
vaseline or silicone oil. Check that the pump is correctly housed in its seat in the filter body.
9.10.5 Circulation pump (standard version)
a. Remove the rear shell
b. Disconnect the circulation hose (and, if present, the venting
hose)
c. Lay the appliance face-down and remove the screw which
secures the support to the base.
d. Bend back the two base anchor tabs and remove the pump
(72)
e. Detach the pump from the filter coupling (or from the heat
exchanger)
f. Detach the wiring connector
g. Detach the thermostat bulb (if present)
When re-assembling, ensure that the O-ring is fitted to the filter
body coupling hose (or to the heat exchanger). Lubricate with
vaseline to facilitate insertion.
9.10.6 Circulation pump - “New Jet” version
Access to the pump is from the base of the appliance:
a. Remove the two screws which secure the pump to the base.
b. Detach the circulation pump assembly from the base.
c. Loosen the clamps and detach the hoses from the pump (73)
d. Detach the cover.
e. Detach the wiring connectors.
f. Remove the circulation pump assembly
9.10.7 Filter/pump assembly - models with Neat cabinet (Jetsy- IZ)
a. Lay the appliance face-down, remove the screws which secure
the filter body (70) and detach the filter from the base.
b. Detach the hoses from the filter body and the pumps.
c. Detach the connectors.
d. Remove the filter/pumps assembly from the base.
9.10.8 Circulation pump - models with Neat cabinet (Jetsy- IZ)
a. Remove the filter/pumps assembly from the base (9.10.7)
b. Remove the screws which secure the circulation pump (74)