05306004
Page
Notice
Date
INSTALLATION
MANUAL
13
6
1004
D0455
D0883
D
D
A
H
B
S
R
E
F
P
P
G
6. Installation/
Putting into service
Steam connection
There is always a risk that a certain
amount of water will be carried in steam.
Water is carried in the lower parts of the
supply tubes, and steam in the upper
parts.
Make a swan neck branch-T on the main
tube to prevent this water damaging the
machine heating system. This will ensure
that only steam is retrieved without any
condensed water.
Steam connection
DN 20 (¾" BSP) female
Maximum supply pressure 1000 kPa
max.
The customer must install a steam flexible
pipe, a manually closing valve lockable in
off position (do not use a 1/4 valve), a
filter and a line steam trap on the supply
side of the machine.
Condensate connection
DN 15 (½" BSP) female
The customer must install a steam flexible
pipe, a purge valve with float closed with
an incondensibles drainage device, a by-
pass, a non-return valve and a manual
closing valve lockable in off position (do
not use a 1/4 valve).
The customer must supply and install the necessary apparatus for the good running of the
steam installation following the skeleton diagram of this page and in conformity with the
present legislation.
A
Finishing cabinet
B
Line trap (recommended)
D
Manual stop valve
E
Filter
F
Steam trap
G
By-pass (needle valve)
H
Non-return valve
P
Steam flexible pipe (recommended)
R
Return of condensates
S
Steam inlet
Содержание FC48
Страница 1: ...05306004 GB 26 2019 Installation manual Finishing cabinet FC48 Translated from french ...
Страница 2: ......
Страница 34: ... ...
Страница 35: ... ...
Страница 36: ...Share more of our thinking at www electroluxprofessional com ...