NOTE : if the flow is insufficient due to an excessive pressure loss, a safety
pressure switch will automatically switch the heating off.
6. Installation/
Putting into service
To prevent any risk of burnings, the vapours' evacuation duct of the
finishing cabinets has to be temperature insulated (to be done by
the customer).
Electric and steam heating specifications.
• Fan maximum flow rate with no pressure : 525 m³/h
• Maximum pressure available with no flow : 85 mm H
2
O
• Average temperature of exhaust at the machine outlet : 90 °C.
Provided (for each machine) an
upper
ventilation of 7 dm²
and a
lower one of 14 dm²
in
your laundry.
Gas heating specifications.
• Fan maximum flow rate with no pressure : 360 m³/h
• Pression maximum disponible à débit nul : 16 mm H
2
O
•
Minimum static depression (natural draught) of the evacuation system : 2 mm H
2
O
per machine
• Average temperature of exhaust at the machine outlet : 85 °C.
Provided (for each machine) an
upper
ventilation of 7 dm²
and a
lower one of 14 dm²
in
your laundry.
For gas heating, therequired combustion fresh air supply should be not less than 2 m
3
/h per
kW, either 40 m
3
/h minimum.
NOTE : the finishing cabinets must have a separate vapours evacuation duct of any
other evacuation (dryer or other equipment).
It is necessary that the fitter carries out a connection dedicated to the finishing
cabinets.