28
electrolux
Gas connection
Gas connection must be carried out
according to the rules in force. The
manufacturing company release the unit,
once tested, adjusted for the kind of gas
stated on the rating plate located on the
back of the range, next to connection pipe.
Be sure that you are going to connect the
unit to the same kind of gas written on the
plate.
Gas connection
LPG :
use the rubber pipe holder «B».
Natural gas :
use the pipe holder «A».
Always insert the gasket «C». Then
proceed with the gas connection, as
indicated in the relevant paragraphs.
Connection using flexible non
metal pipes
When the connection can be easily
inspected in its full extent, there is the
chance to use a flexible pipe according to
the rules in force. The flexible pipe must
be tightly fixed using clamps according to
the rules in force.
The flexible pipe should be made
ready for use in such a way that:
-
nowhere it can reach overtemperature,
other than room temperature, higher
than 30°C; if the flexible pipe, to reach
the cock, must run behind the range,
it must be installed as shown in the
diagram;
-
it is no longer than 1500 mm;
-
it shows no throttles;
-
it is not subject to traction or torsion;
-
it does not get in touch with cutting
edges or corners;
-
it can be easily inspected in order to
check its condition.
ELECTRIC WIRE
FLEXIBLE
RUBBER
GAS PIPELINE
GAS PIPELINE
GAS PIPELINE
GAS PIPELINE
GAS PIPELINE
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
ELECTRIC WIRE
FLEXIBLE
RUBBER
GAS PIPELINE
GAS PIPELINE
GAS PIPELINE
GAS PIPELINE
GAS PIPELINE
Содержание EKG 600102
Страница 1: ...Gas Cooker EKG 600102 instruction booklet UA Газова плита брошура з інструкцією ...
Страница 2: ...2 electrolux ...
Страница 36: ...36 electrolux ...
Страница 70: ...70 electrolux ...
Страница 71: ...electrolux 71 ...
Страница 72: ...35905 0001 05 08 R 0 ...