30
electrolux
by-pass screw
3.
Using a socket spanner 7 unscrew
and remove (see diagram) the noz-
zles replacing them with the ones re-
quired for the kind of gas in use (see
table “Burner characteristics”).
4.
Reassemble the parts following the
same procedure backwards.
Replace the rating label (placed near
the gas supply pipe) with the relevant
one for the new type of gas supply. You
can find this label in the package of the
injectors supplied with the appliance.
These burners do not need any
primary air regulation.
Hob burners - Adjustment of mini-
mum level
To adjust the minimum level:
1.
turn the knob on the position of mini-
mum flame;
2.
remove the knob;
3.
With a thin screwdriver, adjust the
by-pass screw positioned in the
centre of the gas tap control shaft
(see picture). If changing from natu-
ral gas 20 mbar to liquid gas, com-
pletely tighten the adjustment screw
in. If changing from liquid gas to
natural gas 20 mbar, undo the by-
pass screw about 1/2 of a turn. If
changing from natural gas 20 mbar
to natural gas 13 mbar undo the by-
pass screw about 1/4 of a turn. If
changing from liquid gas to natural
gas 13 mbar, undo the by-pass
screw about 3/4 of a turn.
4.
Reassemble the parts following the
same procedure backwards.
Check that, turning quickly the knob
from the maximum position to the
minimum one, the flame does not go out.
Содержание EKG 600102
Страница 1: ...Gas Cooker EKG 600102 instruction booklet UA Газова плита брошура з інструкцією ...
Страница 2: ...2 electrolux ...
Страница 36: ...36 electrolux ...
Страница 70: ...70 electrolux ...
Страница 71: ...electrolux 71 ...
Страница 72: ...35905 0001 05 08 R 0 ...