15 QUICK GUIDE TO THE SPECIAL FUNCTIONS
The table below briefly describes how each of the special functions available to the user and to the Service Engineer can be used:
Function
Activation of the function
Starting the
function
Displaying of the
function
Buttons
Led Buttons
Led Led
Buttons
Led
Short description / Notes
Regeneration
L2
flashes;
The
End of
cycle LED
flashes to
indicate the
level
S2
The
End of cycle
LED
flashes to indicate the
new regeneration level
Pressing button
S2
the no. of flashes increases:
….
….[
1
]..……[
2
]…….[
3
]……....[
4
]…..…[
5
]…….. [
6
]……...[
7
] ….…[
8
]…..…[
9
]……[
10
]
°F… >7 ….. >18 ..…..>25 ….. >32 ….. >39 ….. >50 ….. >64 ….. >75 ….. >90 ... >125
°D… >4 …... >10 ..…. >14 ..... >18 ….. >22 ….. >28 ….. >36 …. >42 …. >50 …. >70
USER (*)
Buzzer
S0
(On/Off)
S2
(
for 3sec)
L2
flashes;
L3
on with
steady light
S2,
before
L3 switches
off
L3
flashes;
L2
on with
steady light
L3
flashes
S2
L3
flashes; the
End of
cycle
LED is on to
indicate if the function is
activated/not activated
Pressing
S2
twice: on = buzzer activated, off = deactivated
S2
L2
flashes
The
End of cycle
LED
flashes to indicate the
type of alarm
memorized.
Pressing button
S2
for other 2 times the other 2 memorised alarms are
displayed flashing…
Alarm
reading
and
Components
check
L2
flashes;
L3
and
L4
on
with steady
light
S2
L3
is on
…from the fourth activation of button
S2,
the single components activate:
[
4
] [
5
] [
6
] [ 7
] [
8
] [ 9
] [10]
ER
PS
EV RR PL DD MV
Cancel
alarms
S2,
before L3
and L4 switch
off
L3
flashes;
L2
and
L4
on with
steady light
L3
flashes
S2
All LEDs and digits flash
for 30 sec
It is advisable to cancel the alarms after each operation.
SERVICE
Test cycle
[
S2
]
S0
(On/Off)
L2
flashes;
L3
and
L4
on
with steady
light
S2
(for two
times)
,
before
L3 and L4
switch off
L4
flashes;
L2
and
L3
on with
steady light
L4
flashes
S2
L2
flashes
The cycle starts automatically.
Exit / Memorize
In order to memorize the functions or exit diagnostics mode, switch the appliance off turning the knob to On/Off position. In most cases the memorization or the exit is
automatic after 60 seconds (in this case the appliance goes to pre-selection mode).
(*)
To activate the “user” functions no cycle has to be selected: to cancel them see 5.2.1; the appliance must be in pre-selection mode.