Installation manual
The factory setting is 3 bar for the pressure.
You must adjust the electrovalves according to the water pressure of your network.
• Unscrew the nut (C) of each electrovalve and screw the screw (B) up to the end,
• For a 1 bar pressure, unscrews the screw (B) of 17 1/3 rounds (26 mm)
• For a 2 bars pressure, unscrews the screw (B) of 4 1/3 rounds (6 mm)
• For a 3 bars pressure, unscrews the screw (B) of 3 1/3 rounds (5 mm)
• For a 4 bars pressure, unscrews the screw (B) of 2 2/3 rounds (4 mm)
• For a 5 bars pressure, unscrews the screw (B) of 2 rounds (3 mm)
• For a 6 bars pressure, unscrews the screw (B) of 1 1/3 rounds (2 mm)
• Screw the nut (C) of each electrovalve.
According to the standard EN1717
The closing sheet (A) is normaly mounted on the machine. If not, ste the side sheet supplied with the machine(ref.
31105197 or ref. 31105124); this allow to reduce the water filling time.
If you must be comply with the standard EN1717, remove this sheet and reduce the water pressure to limit the
splashes by the side hole.