Installation manual
51
16 Steam connection
For transport reasons, the steam electrovalve is dismantled and placed in the cardboard box supplies.
The inlet pipe to the machine has to be fit with a manual stopping valve to ease installation and maintenance and a
flexible steam supply pipe to allow reliable running of automatic weighing system.
Hereunder values apply to the steam pressure:
Recommended pressure: 300 at 600 kPa (3 at 6 kg/cm²) (43.5 at 87 psi)
Limiting of values:
•
mini. 100 kPa (1 kg/cm²) (14.5 psi)
•
maxi. 600 kPa (6 kg/cm²) (87psi)
Connection size: DN 25 (1" BSP male).
Connect the steam installation on the top of the machine (see example sketch).
A
Washer-extractor
S
Steam inlet
Y
Manual stop wheel valve DN 25 (1" BSP) (provided by customer)
P
Steam filter DN 25 (1" BSP) (provided)
F
Steam special flexible pipe DN 25 (1" BSP) (provided) length : 70 cm
U
Pipe union DN 25 male/female (1" BSP) (provided)
Содержание WP4 1100H