Installation manual
9
3.1.1
Barrier partition
The barrier partition (3) shall be built before the installation of the machine.
Centre and align the machine with the barrier partition (3).
Mount the rubber seal (2) in the aluminium section (1).
Fasten the aluminium section (1) with screws in the barrier partition (3).
If machines are to be installed in an existing wall thicker than 100 mm please contact authorized service personnel.
4
C
B
A
3
D
3
5
1
2
fig.6822A
1
Aluminium section
2
Rubber seal
3
Barrier partition
4
Removable barrier partition
5
Minimum 70 mm, maximum 100 mm
mm
A
B
C
D
WB5130H
990
1650
150
40
WB5180H
1050
1650
150
40