Electrical connections
WB5130H
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
200V 3 ~
50/60
9.0
9.3
35
220–240V 1 ~
50/60
10.9–13.0
11.2–13.2
63
220–240V 3 ~
50/60
10.9–13.0
11.2–13.2
35
380–415V 3 ~
50/60
4.0-4.8
4.3–5.0
10
380–415V 3 ~
50/60
10.9–12.9
11.1–13.2
20
440/480V 3 ~
60
13.0
13.3
20
Non heated/Steam
heated
200V 3 ~
50/60
-
1.3
10
WB5180H
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
200V 3 ~
50/60
12.5
12.9
50
220–240V 3 ~
50/60
9.1–10.8
9.4–11.1
35
220–240V 3 ~
50/60
15.1–18.0
15.5–18.3
50
380–415V 3 ~
50/60
9.0–10.8
9.4–11.1
20
380–415V 3 ~
50/60
15.0–17.9
15.4–18.3
35
440/480V 3 ~
60
18.0
18.4
25
Non heated/Steam
heated
200V 3 ~
50/60
-
2.4
10
8.3
Machine connection
8.3.1
Single-phase connection
Connect the earth and other two wires as shown.
1NAC
L1
N
1AC
L1
L2