4.2
Siting
Install the machine close to a floor drain or open drain.
We strongly recommend to drain under the machine for hygiene and safety reasons. Make sure the drain connection
is tight. Otherwise the warm steam from the drainage water can damage the components
The machine should be positioned so that there is plenty of room for working, both for the user and service personnel.
The figure shows minimum distance to a wall and/or other machines.
10
00
m
m
/
39
3
/8
in
ch
10
00
m
m
/ 3
9 3
/8 in
ch
10
00
m
m
/ 3
9 3
/8 in
ch
4.3
Mechanical installation
If the machine is not to be mounted on a base the machine must be fastened to the floor.
The table shows the correct drilling points.
Mark and drill two holes (
⌀
10 mm) about 50 mm deep in the positions shown.
FRONT
A
C
B
H
G
E
F
D
fig.6943
mm
A
B
C
D
E
F
G
H
WB5130H
Standard
730
515
90
260
515
195
680
110
Machine with
AS
815
515
50
260
515
195
680
110
Machine
without base
640
490
140
275
515
195
725
120
WB5180H
Standard
790
575
90
290
595
185
730
110
Machine with
AS
875
575
50
290
595
185
730
110
Machine
without base
715
545
125
300
595
185
810
120