18
User manual
Parameters in main wash, pre wash, rinse, pre rinse and soaking modules:
Temperature settings
• Filling with pre heating
– Set if the water shall be heated to max; “Filling max. temperature”, during the filling phase. Can be used to shorten the
total program time.
• Filling max. temperature
– Set the max water temperature during the filling phase. The temperature will be adjusted by opening and closing the
hot/cold water valves and/or turning on/off heating.
• Wash temperature
– Set the wash temperature between 10–95
℃
.
• Maintain temperature
– Set if the set wash temperature shall be maintained during the whole washing time. This is mainly used for thermal
disinfection.
Tip: In a main wash, following a pre wash, the “Filling max. temperature” can normally be set as high as the “Wash
temperature”.
Time settings
The times are set in hours/minutes/seconds.
• Filling
– Set the absorbing/wetting/soaking time. Time starts to count down when set level is reached. During this phase the
textile will absorb water and the water valves will open to refill up to the set level.
• Washing
– Set the washing time. Time starts to count down when set level and temperature conditions are fulfilled.
• Start washing timer at
– Select from a drop down list if the washing time should start counting down when the set level is reached or when the
set wash temperature is reached.
Tip: In a main wash, following a pre wash, the time in the filling phase can normally be shortened since the textile al-
ready has absorbed water in the pre wash.
Water level settings
• Level
– Select water level from the drop down list. The relationship between drum diameter and level in mm is not linear.
Therefore, there is a list of proven levels that are adapted to give the same results regardless of drum size.
• Smart filling
– Select smart filling to get the most accurate water level.
Note!
If smart filling is selected the drum rotation will be stopped at the end of the filling.
For water level settings, please refer to section
.
Action and speed settings
Select drum rotation action during the different steps from the drop down list with predefined and tested rotation and standing
still times.
Select drum speed during the different steps. The value is set between 0–1.00G.
For action and speed settings, please refer to section
.
Dosing of chemicals
For each of the chemicals the following can be set:
• At temperature
–
Set if the dosing of the selected chemical should start before or after the dosing temperature that is set in header mod-
ule is reached.
• Load
– Set the amount of chemical(s) that shall be dosed in the step/module. The amount is set in ml/kg of load. The same
dosage amount per kg load gives different dosing times depending on how much load there is in the machine.
The amount of chemicals will however never be less than the amount related to the % of the machine's capacity set in the
parameter “Min. chemical dosing”.
Example: Min. chemical dosing: 30%, weight of the load is 20% of machine capacity. Dosing will be according to 30%of
machine capacity.
If the program does not have a weighing module the dosing will be according to the machines capacity.