Outdoor Board Fault Codes
Displayed
Content
Fault Definition
Fault Cause
EEA
EEPROM fault
Fault of EEPROM on coordination board
EEB
EEPROM fault
Fault of EEPROM on outdoor board
E0
Fault of communication between coordination
board and driver board
No communication or communication fault between
coordination board and driver board
EC
Fault of communication between variable
frequency module and outdoor unit
Communication fault between the outdoor unit power
board and module
E0A
1# indoor communication fault
No communication or communication fault between 1#
indoor and outdoor
E0B
2# indoor communication fault
No communication or communication fault between 2#
indoor and outdoor
E0C
3# indoor communication fault
No communication or communication fault between
3# indoor and outdoor
E0D
4# indoor communication fault
No communication or communication fault between
4# indoor and outdoor
E0E
5# indoor communication fault
No communication or communication fault between
5# indoor and outdoor
E10
Weak current communication fault
Communication fault of coordination board and
outdoor unit board
E9
Variable frequency drive/module fault
Driving occurs 3 times within 30 minutes or module
protection
EP
Compressor shell roof switch fault
Too high temperature or the shell top of compressor
or temperature switch is broken
EU
Voltage sensor fault
The system is unable to sense voltage
E3
T3 temperature sensor fault
Short circuit or open circuit of outdoor coil temperature
sensor
E7
T4 temperature sensor fault
Short circuit or open circuit of outdoor ambient
temperature sensor
E8
Exhaust temperature sensor fault
Short circuit or open circuit of exhaust temperature
sensor
EH
Air return temperature sensor fault
Short circuit or open circuit of air return temperature
sensor
EtA
1#T2B1 temperature sensor fault
Short circuit or open circuit of outlet temperature
sensor of 1# outdoor coil
EtB
2#T2B2 temperature sensor fault
Short circuit or open circuit of outlet temperature
sensor of 2# outdoor coil
EtC
3#T2B3 temperature sensor fault
Short circuit or open circuit of outlet temperature
sensor of 3# outdoor coil
EtD
4#T2B4 temperature sensor fault
Short circuit or open circuit of outlet temperature
sensor of 4# outdoor coil
EtE
5#T2B5 temperature sensor fault
Short circuit or open circuit of outlet temperature
sensor of 5# outdoor coil
P0
IPM module protection
Compressor drive module is in abnormal status
P9
Compressor drive fault protection
Compressor drive is in abnormal status or unable to
star
P9
HP dial setting fault
The type of driver board does not match that of
compressor
P1
Low-voltage protection
Input voltage is lower than 160V?5V
P2
Compressor current protection
Running current exceeds the set value
P4
Exhaust gas high temperature protection
Exhaust temperature exceeds the shutdown
protection value
H1
High-voltage switch protection
High-voltage switch is in abnormal status
H2
Low-voltage switch protection
Low-voltage switch is in abnormal status
P6
Refrigerator T3 overheat protection
Outdoor pipe temperature of refrigerator exceeds the
set value