![ElectrIQ eiQ-12K12KC24KWMINV Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/electriq/eiq-12k12kc24kwminv/eiq-12k12kc24kwminv_user-and-installation-manual_2379333014.webp)
14
1. Drill a piping hole (90) through external wall at a slight angle
2. Insert the piping sleeve in to the hole to prevent damage to the
connecting copper pipes and wiring when they are passed through the
1. Always install the rear bracket horizontally. The pipes in the unit can be installed to the left
(default) or can be channeled to the right side. If the drain pipe needs to be changed from left to
right then the rubber bung on the right side needs to be moved to the left outlet to avoid leakage.
The outlet of the water tray needs adjusting down so the water follows the gravity fall. if the drains
is running anti-gravitationally at any stage above the tray level or the run is longer than 5 meters
inline water pump must be used
2. Fix the rear bracket on the wall with screws
3. Be sure the correct screws for the type of wall where is installed are used and the mounted
Содержание eiQ-12K12KC24KWMINV