Dehumidification Level

 Controls Keys 

(2)

 

Use the key 

(2)

 to select between continuous mode 

and 40-70% humidity 

If  no  selection  is  made  the  unit  will  work  with  pre-set  to  50%RH  which  is  the 
recommended setting 

Continuous mode

 

 

humidistat is disabled, unit will dry until set time or tank full

 

Humidity  set  to 

40%  RH;

  set  to  achieve  room  humidity  of  around  40%  good  for 

quick  drying  boost  on  initial  run  or  emergencies,  not  recommended  for  long 
normal operation in domestic environment 
Humidity set to 

50% RH;

 recommended setting, great for domestic operation and 

dry storage 
Humidity  set  to 

60%  RH;

  great  for  personal  comfort  and  applications  where  50% 

RH is considered too dry 
Humidity set to 

70% RH;

 ideal for unoccupied properties or where economical run 

is needed without the need to go drier than 70% RH 

Indicator led lights 

(5) Quiet mode 

  lighten when quiet low fan mode is selected

 

(6) Turbo mode

lighten when turbo high fan mode is selected

 

(7) Laundry mode

lighten when laundry mode is selected

 

(8)  Humidity  and  timer  display 

two  digits  led  display  shows  room  humidity 

(35-95%RH) or set timer

 

(9)  Humidity  selection

  shows  40%  50%  60%  70%  and  continuous  mode 

 

according to key 

(2)

 selection

 

(10) Timer on led light 

 

lighten while stopping timer is in operation off if the 

timer is not activated

 

(11) Power on led light 

Lighten continuously is unit is operating normally 
The  led  indicator  will  blink  intermittently  when  the  unit  is  tipped  over  or 
when  the  unit  is  turned  off  but  the  fan  continues  to  operate  for  few 
minutes to dissipate the heat and empty the desiccant disc 

(12) Tank Full led light 

red light on if tank full and required to be emptied of 

is not pushed in correctly 

NOTES: 

This unit is equipped with tilt protection. When the unit is tilted will stop automatically, 

the  POWER  indicator  will  turn  into  RED  and  the  unit  will  beep  3  times.  After  repositioning  the 
unit, press 

Power

 key to restart.

 

DESD10L has intelligent self-diagnosis. If the humidity sensor, heating element or tip-over device 
is out of function, the unit will beep 3 times, the POWER indicator would turn RED and the unit 
will turn OFF.

 

 

Содержание DESD10L

Страница 1: ...laundry mode DESD10L USER MANUAL Thank you for choosing ElectrIQ Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www electr...

Страница 2: ...Contents Safety instructions 2 Features 4 Parts 5 Control panel 6 Quick operation guide 7 Operation 9 Positioning 12 Water Drainage 13 Care and Maintenance 16 FAQ 17 Troubleshooting 19 Technical Data...

Страница 3: ...o not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qual...

Страница 4: ...eased or accumulate Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills For maximum performance the minimum distance from a wall should b...

Страница 5: ...auto stop function 9 Antibacterial filter sterilizes the air 10 Recessed carry handle for portability 11 Anti tilt safe design ElectrIQ desiccant dehumidifiers use compressor free desiccant technology...

Страница 6: ...y for 24 hrs To reduce noise levels Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running PARTS 1 Recessed carrying Handle 2 Air inlet and grill bac...

Страница 7: ...hrs 4 Power ON key 5 12 function indicator led lights 5 Quiet mode 6 Turbo mode 7 Laundry mode 8 Humidity and timer display shows room humidity or set timer 9 Humidity selection led lights 40 70 RH an...

Страница 8: ...he set humidity level than will work in low fan mode until humidity increases again Laundry mode Heater and fan are both on all the time to achieve maximum dehumidification and dry the clothes Humidis...

Страница 9: ...mode lighten when laundry mode is selected 8 Humidity and timer display two digits led display shows room humidity 35 95 RH or set timer 9 Humidity selection shows 40 50 60 70 and continuous mode acco...

Страница 10: ...t disk and prevent mould growth Setting the Laundry Mode Press mode selection until laundry led will turn on Laundry mode will set the fan and heater on to maximum and humidistat control will be disab...

Страница 11: ...10 minutes on automatic selection mode 50 RH until the humidistat is able to read correctly the humidity in the room Press dehumidify level key 2 to select the desired humidistat controls from contin...

Страница 12: ...damage Warning Using poor quality sockets extensions or overloading the circuits may cause damage to the machine or may start a fire 5 When switching OFF the machine do not simply unplug the unit from...

Страница 13: ...nit Please observe figure bellow in installing the unit Your ELECTRIQ dehumidifier will begin to protect your home from the harmful effects of excessive moisture as soon as it is turned on Excess mois...

Страница 14: ...it should not be placed directly against a radiator or other heat source When positioning your ELECTRIQ dehumidifier ensure that it is placed securely on a level surface clear of any obstacle that may...

Страница 15: ...do not touch sensors or any parts which are situated behind tank Doing so may damage the product Be sure to push the tank gently all the way into the unit Banging the bucket against anything or failin...

Страница 16: ...the place Then direct the pipe to a suitable drainage point This unit uses gravity fall to dispose water hence the drain should be lower than the dehumidifier water outlet Be sure to run the water pip...

Страница 17: ...from socket before maintenance and let it dry before reuse 1 Remove the filters from the unit Tap the dust away first 2 Clean the carbon and the mesh filter with a vacuum cleaner or soft brush 3 If di...

Страница 18: ...hort circuit or become a fire risk Please avoid pulling the cord twisting or pressing it and keep it away from pets If the power cord is damaged power the unit off and unplug if immediately Contact an...

Страница 19: ...s is normal operation The intelligent logic of your machine will save you money Unless you dry clothes we recommend to use the unit in 50 60 RH If you find that you still have condensation on your win...

Страница 20: ...ture into air 1 We recommend using a dehumidifier with a greater capacity Call customer service line for advice 2 We recommend using a dehumidifier with a greater capacity 3 Consider using an alternat...

Страница 21: ...side 2 Check if filters are clean 3 if fault persists then call the call the service centre Machine not switching off the heater when desired humidity is reached Temperature and relative humidity sen...

Страница 22: ...ow 200m3 hr Power in different Settings 470 780 W Low High Setting Timer 1 24 hours Working Temperature 1 32 C Noise 48 dB Water tank Capacity 3 5L Net Weight 8 5Kg Body Size H525 x W200 x D445 mm DES...

Страница 23: ...the mains Is the fuse OK 3 Switch the unit on and wait three minutes to see if the issue is resolved 4 Check whether the water tank is full 5 Have you followed the troubleshooting procedures If the un...

Отзывы: