ElectrIQ DESD10L Скачать руководство пользователя страница 19

18 

 

Amount of water collected and size of the tank 

• 

When  you  first use  your  dehumidifier  it  will  work  harder to  reduce 

the room humidity down to 50%RH (default mode or set to continuous 
or  40%RH).    This  is  the  time  when  it  will  produce  the  most  water  and 
need  emptying  most  frequently  even  2-3  times  /  day.    As  the  room 
becomes dryer the dehumidifier collects less water and will takes longer 
to  fill  the  tank,  this  is  perfectly  normal.    When  the  target  relative 
humidity  has  been  reached  the  dehumidifier  will  stop  collecting  water 
and  going  longer  in  fan  only  mode,  this  is  normal  operation.  The 
intelligent logic of your machine will save you money. 
• 

Unless you dry clothes, we recommend to use the unit in 50-60%RH 

• 

If you find that you still have condensation on your windows or you 

need to dry the air further then us the 40%RH or continuous mode with 
fan  set  to  turbo  mode.  This  might  well  be  necessary  if  you  have  single 
glazed  windows,  house  that  is  poorly  insulated  or  if  the  outside  air 
temperature drops towards freezing. Using in Turbo mode will add more 
heat  to  your  room  and  reduce  your  heating  bill  as  dry  air  will  heat 
quicker. 
• 

For unoccupied properties, garages, etc. use 60-70% RH with fan in 

Turbo or Quiet mode according to your needs. That will ensure minimum 
power consumption while will prevent moisture related issues. 

Содержание DESD10L

Страница 1: ...laundry mode DESD10L USER MANUAL Thank you for choosing ElectrIQ Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www electr...

Страница 2: ...Contents Safety instructions 2 Features 4 Parts 5 Control panel 6 Quick operation guide 7 Operation 9 Positioning 12 Water Drainage 13 Care and Maintenance 16 FAQ 17 Troubleshooting 19 Technical Data...

Страница 3: ...o not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qual...

Страница 4: ...eased or accumulate Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills For maximum performance the minimum distance from a wall should b...

Страница 5: ...auto stop function 9 Antibacterial filter sterilizes the air 10 Recessed carry handle for portability 11 Anti tilt safe design ElectrIQ desiccant dehumidifiers use compressor free desiccant technology...

Страница 6: ...y for 24 hrs To reduce noise levels Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running PARTS 1 Recessed carrying Handle 2 Air inlet and grill bac...

Страница 7: ...hrs 4 Power ON key 5 12 function indicator led lights 5 Quiet mode 6 Turbo mode 7 Laundry mode 8 Humidity and timer display shows room humidity or set timer 9 Humidity selection led lights 40 70 RH an...

Страница 8: ...he set humidity level than will work in low fan mode until humidity increases again Laundry mode Heater and fan are both on all the time to achieve maximum dehumidification and dry the clothes Humidis...

Страница 9: ...mode lighten when laundry mode is selected 8 Humidity and timer display two digits led display shows room humidity 35 95 RH or set timer 9 Humidity selection shows 40 50 60 70 and continuous mode acco...

Страница 10: ...t disk and prevent mould growth Setting the Laundry Mode Press mode selection until laundry led will turn on Laundry mode will set the fan and heater on to maximum and humidistat control will be disab...

Страница 11: ...10 minutes on automatic selection mode 50 RH until the humidistat is able to read correctly the humidity in the room Press dehumidify level key 2 to select the desired humidistat controls from contin...

Страница 12: ...damage Warning Using poor quality sockets extensions or overloading the circuits may cause damage to the machine or may start a fire 5 When switching OFF the machine do not simply unplug the unit from...

Страница 13: ...nit Please observe figure bellow in installing the unit Your ELECTRIQ dehumidifier will begin to protect your home from the harmful effects of excessive moisture as soon as it is turned on Excess mois...

Страница 14: ...it should not be placed directly against a radiator or other heat source When positioning your ELECTRIQ dehumidifier ensure that it is placed securely on a level surface clear of any obstacle that may...

Страница 15: ...do not touch sensors or any parts which are situated behind tank Doing so may damage the product Be sure to push the tank gently all the way into the unit Banging the bucket against anything or failin...

Страница 16: ...the place Then direct the pipe to a suitable drainage point This unit uses gravity fall to dispose water hence the drain should be lower than the dehumidifier water outlet Be sure to run the water pip...

Страница 17: ...from socket before maintenance and let it dry before reuse 1 Remove the filters from the unit Tap the dust away first 2 Clean the carbon and the mesh filter with a vacuum cleaner or soft brush 3 If di...

Страница 18: ...hort circuit or become a fire risk Please avoid pulling the cord twisting or pressing it and keep it away from pets If the power cord is damaged power the unit off and unplug if immediately Contact an...

Страница 19: ...s is normal operation The intelligent logic of your machine will save you money Unless you dry clothes we recommend to use the unit in 50 60 RH If you find that you still have condensation on your win...

Страница 20: ...ture into air 1 We recommend using a dehumidifier with a greater capacity Call customer service line for advice 2 We recommend using a dehumidifier with a greater capacity 3 Consider using an alternat...

Страница 21: ...side 2 Check if filters are clean 3 if fault persists then call the call the service centre Machine not switching off the heater when desired humidity is reached Temperature and relative humidity sen...

Страница 22: ...ow 200m3 hr Power in different Settings 470 780 W Low High Setting Timer 1 24 hours Working Temperature 1 32 C Noise 48 dB Water tank Capacity 3 5L Net Weight 8 5Kg Body Size H525 x W200 x D445 mm DES...

Страница 23: ...the mains Is the fuse OK 3 Switch the unit on and wait three minutes to see if the issue is resolved 4 Check whether the water tank is full 5 Have you followed the troubleshooting procedures If the un...