Setting the Stopping Timer 

On selecting stopping timer key 

(3) 

the 2 digits LED display will cycle 

through 1-24 showing the number hours after which the 
dehumidifier will stop. The displayed time will revert to humidity 
display 8 seconds after selection was made.   

When selecting '4 hours' for example the unit will stop operating 

after 4 hours with selected humidity / fan settings. Tank full before 
the selected time will stop the unit. This setting is ideal for drying 
laundry. No selection made will mean the unit operates 
continuously subject to tank full stopping the unit earlier. 
Press timer key again at any time to cancel or change the timer 
settings 

Setting the Dehumidification level 

Start the unit and leave it for 5-10 minutes on automatic selection 

mode (50%RH) until the humidistat is able to read correctly the 
humidity in the room. 

Press dehumidify level key 

(2)

 to select the desired humidistat 

controls from continuous operation to 40% 50% 60% 70%. 

While pressing the selection key 

(2)

 the corresponding indicator 

(9)

 

cycles the humidistat set range for this unit from 40% through 50% 
70%, 60% back to continuous mode.   
 

Intelligent dehumidification and power saving 

Your ElectrIQ dehumidifier features an intelligent micro CPU that 

ensure maximum water extraction with minimum power use for the 
selection made. 

The unit will try to maintain humidity level selected in the room by 
turning off the heating element when the desired humidity is 
reached. Note that according to the space where the unit is used, 
obstacles in the direct flow, extra humidity being added at any time, 
settings selected, as well as other environmental factors the results 
may vary.   

Содержание DESD10L

Страница 1: ...laundry mode DESD10L USER MANUAL Thank you for choosing ElectrIQ Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www electr...

Страница 2: ...Contents Safety instructions 2 Features 4 Parts 5 Control panel 6 Quick operation guide 7 Operation 9 Positioning 12 Water Drainage 13 Care and Maintenance 16 FAQ 17 Troubleshooting 19 Technical Data...

Страница 3: ...o not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qual...

Страница 4: ...eased or accumulate Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills For maximum performance the minimum distance from a wall should b...

Страница 5: ...auto stop function 9 Antibacterial filter sterilizes the air 10 Recessed carry handle for portability 11 Anti tilt safe design ElectrIQ desiccant dehumidifiers use compressor free desiccant technology...

Страница 6: ...y for 24 hrs To reduce noise levels Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running PARTS 1 Recessed carrying Handle 2 Air inlet and grill bac...

Страница 7: ...hrs 4 Power ON key 5 12 function indicator led lights 5 Quiet mode 6 Turbo mode 7 Laundry mode 8 Humidity and timer display shows room humidity or set timer 9 Humidity selection led lights 40 70 RH an...

Страница 8: ...he set humidity level than will work in low fan mode until humidity increases again Laundry mode Heater and fan are both on all the time to achieve maximum dehumidification and dry the clothes Humidis...

Страница 9: ...mode lighten when laundry mode is selected 8 Humidity and timer display two digits led display shows room humidity 35 95 RH or set timer 9 Humidity selection shows 40 50 60 70 and continuous mode acco...

Страница 10: ...t disk and prevent mould growth Setting the Laundry Mode Press mode selection until laundry led will turn on Laundry mode will set the fan and heater on to maximum and humidistat control will be disab...

Страница 11: ...10 minutes on automatic selection mode 50 RH until the humidistat is able to read correctly the humidity in the room Press dehumidify level key 2 to select the desired humidistat controls from contin...

Страница 12: ...damage Warning Using poor quality sockets extensions or overloading the circuits may cause damage to the machine or may start a fire 5 When switching OFF the machine do not simply unplug the unit from...

Страница 13: ...nit Please observe figure bellow in installing the unit Your ELECTRIQ dehumidifier will begin to protect your home from the harmful effects of excessive moisture as soon as it is turned on Excess mois...

Страница 14: ...it should not be placed directly against a radiator or other heat source When positioning your ELECTRIQ dehumidifier ensure that it is placed securely on a level surface clear of any obstacle that may...

Страница 15: ...do not touch sensors or any parts which are situated behind tank Doing so may damage the product Be sure to push the tank gently all the way into the unit Banging the bucket against anything or failin...

Страница 16: ...the place Then direct the pipe to a suitable drainage point This unit uses gravity fall to dispose water hence the drain should be lower than the dehumidifier water outlet Be sure to run the water pip...

Страница 17: ...from socket before maintenance and let it dry before reuse 1 Remove the filters from the unit Tap the dust away first 2 Clean the carbon and the mesh filter with a vacuum cleaner or soft brush 3 If di...

Страница 18: ...hort circuit or become a fire risk Please avoid pulling the cord twisting or pressing it and keep it away from pets If the power cord is damaged power the unit off and unplug if immediately Contact an...

Страница 19: ...s is normal operation The intelligent logic of your machine will save you money Unless you dry clothes we recommend to use the unit in 50 60 RH If you find that you still have condensation on your win...

Страница 20: ...ture into air 1 We recommend using a dehumidifier with a greater capacity Call customer service line for advice 2 We recommend using a dehumidifier with a greater capacity 3 Consider using an alternat...

Страница 21: ...side 2 Check if filters are clean 3 if fault persists then call the call the service centre Machine not switching off the heater when desired humidity is reached Temperature and relative humidity sen...

Страница 22: ...ow 200m3 hr Power in different Settings 470 780 W Low High Setting Timer 1 24 hours Working Temperature 1 32 C Noise 48 dB Water tank Capacity 3 5L Net Weight 8 5Kg Body Size H525 x W200 x D445 mm DES...

Страница 23: ...the mains Is the fuse OK 3 Switch the unit on and wait three minutes to see if the issue is resolved 4 Check whether the water tank is full 5 Have you followed the troubleshooting procedures If the un...