background image

 

 

 

should  not  be  used  to  support  the  full 
weight  of  the  dehumidifier.  When 
carrying  the  unit,  it  should  be  kept 
upright and suifficiently supported from 
its base.  

 

The handle should not be used if there 
are any signs of damage to its fixings. 

 

The appliance must be placed in a room 
without sources of ignition (for example: 
open 

flames, 

an 

operating 

gas 

appliance  or  an  operating  electric 
heater). 

 

R290  refrigerant  gas  complies  with 
European environmental directives. 

 

R290 has a low GWP (Global Warming 
Potential) of 3. 

 

The  CD12LE  and  CD12LEB  contains 
about 50g of R290 refrigerant gas. 

 

The  CD20LE  and  CD20LEB  contains 
about 80g of R290 refrigerant gas. 

 

Do not use or store the appliance in an 
unventilated space with an area smaller 
than 4m

2

 per unit.  

 

If  the  appliance  is  installed,  used  or 
stored  in  an  unventilated  room,  the 
room  must  be  such  as  to  prevent 
stagnation 

of 

possible 

leaks 

of 

refrigerant  gas  as  there  could  be  a 
danger  of  fire  or  explosion  should  the 
refrigerant  come  into  contact  with 
electric heaters, stoves or other sources 
of ignition. 

 

Refrigerant gas may be odourless.  

 

Do not use the product and contact the 
retailer  for  advice,  if  damage  has 
occurred  to  the  unit  which  may  have 
compromised the refrigerant system. 

 

Any  repairs  or  maintenance  must  only 
be carried out on the unit by a suitably 
qualified engineer.  Before opening and 
servicing  the  unit  the  authorized 
engineer  must  be  in  possession  of  a 
copy  of  the  manufacturer’s  service 
manual  and  must  follow  the  safety 
information contained within it to ensure 

all hazards are minimized. 

 

The  refrigerant  system  should  not  be 
perforated or punctured. 

 

Do  not  place  the  unit  next  to  heat 
sources (e.g. electrical fires, fireplaces, 
etc.)  

 

Avoid  mishandling  the  dehumidifier. 
Dropping,  throwing  the  unit  can  cause 
damage  to  its  internals  and  increases 
the risks of operating it.  

 

Do  not  store  or  use  gasoline,  petrol, 
paint,  solvents  or  other  flammable 
vapours or liquids in the vicinity of this 
dehumidifier or any other appliance.  

 

This  dehumidifier  must  not  be  used  in 
spaces 

where 

there 

is 

a  high 

concentration of gases, solvent or other 
volatile  organic  compounds;  in  very 
dusty  environments;  in  any  domestic, 
commercial  or  industrial  environment 
where the air composition is flammable.  

  

ENERGY SAVING AND UNIT SAFETY 

PROTECTION TIPS  

 

 

Do not cover or restrict the airflow from 
the outlet or inlet grills. Do not operate 
and follow troubleshoot procedure if the 
self-opening  louvers  do  not  open  on 
power on.   

 

For 

maximum 

performance 

the 

minimum distance from a wall or objects 
should be 20 cm  

 

Keep the filters or grills of the unit clean. 
Under normal conditions, filters or grills 
should  only  need  cleaning  once  every 
three weeks (approximately).   

 

Since  the  filters  remove  airborne 
particles, 

more 

frequent 

cleaning 

maybe necessary, depending on the air 
quality.  Vacuum  both  mesh  and 
optional HEPA filter and wash the mesh 
filters  with  hot  soapy  water  and  dry 
them  before  placing  them  back  in  the 
unit.  

 

 

 

Содержание CD12LE

Страница 1: ...LEB 12 Litres per day CD20LE CD20LEB 20 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future reference Visi...

Страница 2: ...UTANTS 4 APPLIANCE DIAGRAM 5 FEATURES 6 INSTALLATION 6 FITTING THE OPTIONAL FILTERS 6 CONTROL PANEL 7 OTHER FEATURES AND INDICATORS 9 QUICK REFERENCE GUIDE 10 POSITIONING THE DEHUMIDIFIER 11 WATER DRA...

Страница 3: ...tlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the power cord or plug is damaged Ensure the power co...

Страница 4: ...ized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information contained within it to ensure all hazards are minimized The refrigerant system...

Страница 5: ...tants include bacteria viruses dust mites and pollen Emissions from electronic office equipment Many studies including those from EPA and the University of California Berkley have reported that emissi...

Страница 6: ...Replacement filters are available from the retailer under code ACFIL CDLEX HEPA FILTER Filters are available from the retailer under code HEPA CDLEX Note Diagrams are for illustrative purposes only T...

Страница 7: ...astors and is designed to extract unwanted humidity while saving money due to it s power saving logic It features an intelligent humidistat where the desired relative humidity can be adjusted in incre...

Страница 8: ...continuously at high fan speed to remove the most moisture possible This is ideal for drying clothes UP DOWN HUMIDITY SETTING Press the UP and DOWN buttons to select the desired relative humidity lev...

Страница 9: ...ions to improve indoor air quality The relevant LEDs above the button will illuminate to show which function is currently activated LOCK Press and hold the FUNCTION button for 3 seconds to activate th...

Страница 10: ...oom with a temperature between 12 C and 20 C it will enter the defrost mode roughly every 45 minutes HUMIDISTAT CONTROL AND FAN COMPRESSOR OPERATION When the humidity of the room is 2 lower than the d...

Страница 11: ...e fan moves the air around the room ensuring the entire air in the room is processed and humidity correctly measured DEHUMIDIFY MODE This is the standard operating mode for which the desired humidity...

Страница 12: ...n for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and m...

Страница 13: ...into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosure The water...

Страница 14: ...over gently approximately every 2 3 weeks If the mesh filter is dirty hoover it if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit When filter c...

Страница 15: ...re a distance of at least 20 cm between the unit walls Airflow seems weak Are the filters dirty or clogged Please service the filters regularly as per the user manual Unit is noisy during operation Is...

Страница 16: ...unit may be defrosting The ambient operating range is between 5 C and 35 C with a relative humidity ranging from 30 to 80 For maximum efficiency use the unit between 15 C and 32 C Sometimes cold and...

Страница 17: ...to operate call 0330 390 3061 or complete the online form Office hours 9AM 5PM Monday to Friday Unit J6 Lowfields Business Park Lowfields Way Elland West Yorkshire HX5 9DA Recycling facilities are no...