CARE AND MAINTENANCE 

 

Always shut off the unit and unplug from the mains before cleaning or performing any maintenance. When it 
is not in use for long periods it is advisable to remove the plug from the power socket. Do not use chemical 
solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit.   
 

 

 

1. CLEAN THE GRILLE AND CASE 

 

Use  water  and  a  mild  detergent  to  clean  the 
washable  mesh  filter.  Do  not  use  bleach  or 
abrasives.  Do  not  splash  water  directly  onto  the 
main unit. Doing so may cause an electrical shock 
and  can  lead  to  the  insulation  to  deteriorate,  or 
cause  the  unit  to  rust.  The  air  intake  and  outlet 
grilles  get  soiled  easily,  so  use  a  vacuum 
attachment  or  soft  brush  to  clean.  Wipe  the 
dehumidifier body with a soft damp cloth or kitchen 
towel.  

  

 
 
Remove the filter housing.  If the optional filters are fitted, remove them from the frame and hoover gently 
approximately every 2-3 weeks.  
If the mesh filter is dirty hoover it, if it is heavily soiled wash it with warm soapy water and dry thoroughly 
before reinserting it in the unit. When filter cleaning is finished and filters are dry placed them back into the 
unit. The optional filters should be replaced every 3 

– 6 months. 

 
NOTE:

  While the HEPA and Carbon filters are optional, never run the unit without the mesh filter housing 

correctly inserted.  

 

 

2. CLEAN THE WATER TANK 

 

Every few weeks, clean the tank to prevent growth of mould, mildew and bacteria. Partially fill the tank with 
clean water and add a little mild detergent. Swish it around and than empty the tank and rinse.  

NOTE:

 Do not use a dishwasher to clean the tank. After cleaning and drying, the tank must be reinserted 

securely into dehumidifier in order to restart operation.  

 

 

END OF SEASON MAINTENANCE    

1.

 

Empty and clean the water tank.   

2.

 

Clean the unit and the filters as per cleaning procedure above.  

3.

 

Coil the power cord on the special cord storage rest at the back of the unit.  

4.

 

Cover the unit and keep it in a dry place.  

 

 

Содержание CD12LE

Страница 1: ...LEB 12 Litres per day CD20LE CD20LEB 20 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future reference Visi...

Страница 2: ...UTANTS 4 APPLIANCE DIAGRAM 5 FEATURES 6 INSTALLATION 6 FITTING THE OPTIONAL FILTERS 6 CONTROL PANEL 7 OTHER FEATURES AND INDICATORS 9 QUICK REFERENCE GUIDE 10 POSITIONING THE DEHUMIDIFIER 11 WATER DRA...

Страница 3: ...tlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the power cord or plug is damaged Ensure the power co...

Страница 4: ...ized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information contained within it to ensure all hazards are minimized The refrigerant system...

Страница 5: ...tants include bacteria viruses dust mites and pollen Emissions from electronic office equipment Many studies including those from EPA and the University of California Berkley have reported that emissi...

Страница 6: ...Replacement filters are available from the retailer under code ACFIL CDLEX HEPA FILTER Filters are available from the retailer under code HEPA CDLEX Note Diagrams are for illustrative purposes only T...

Страница 7: ...astors and is designed to extract unwanted humidity while saving money due to it s power saving logic It features an intelligent humidistat where the desired relative humidity can be adjusted in incre...

Страница 8: ...continuously at high fan speed to remove the most moisture possible This is ideal for drying clothes UP DOWN HUMIDITY SETTING Press the UP and DOWN buttons to select the desired relative humidity lev...

Страница 9: ...ions to improve indoor air quality The relevant LEDs above the button will illuminate to show which function is currently activated LOCK Press and hold the FUNCTION button for 3 seconds to activate th...

Страница 10: ...oom with a temperature between 12 C and 20 C it will enter the defrost mode roughly every 45 minutes HUMIDISTAT CONTROL AND FAN COMPRESSOR OPERATION When the humidity of the room is 2 lower than the d...

Страница 11: ...e fan moves the air around the room ensuring the entire air in the room is processed and humidity correctly measured DEHUMIDIFY MODE This is the standard operating mode for which the desired humidity...

Страница 12: ...n for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and m...

Страница 13: ...into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosure The water...

Страница 14: ...over gently approximately every 2 3 weeks If the mesh filter is dirty hoover it if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit When filter c...

Страница 15: ...re a distance of at least 20 cm between the unit walls Airflow seems weak Are the filters dirty or clogged Please service the filters regularly as per the user manual Unit is noisy during operation Is...

Страница 16: ...unit may be defrosting The ambient operating range is between 5 C and 35 C with a relative humidity ranging from 30 to 80 For maximum efficiency use the unit between 15 C and 32 C Sometimes cold and...