background image

11 

 

 

 

POSITIONING THE DEHUMIDIFIER 

 

A badly positioned dehumidifier will have little effect. In positioning the dehumidifier please ensure circulation 

of air in not restricted around the unit.   

  

Allow at least 20 cm space around the unit. This dehumidifier is designed only for indoor residential or small 

office applications and any commercial or industrial use will invalidate the warranty.   

 

 

Use in an enclosed area for maximum efficiency. Close all doors, windows to create an effective operating 

environment. Do not use outdoors.  

 

Your electriQ dehumidifier will begin to protect your space from the harmful effects of excessive moisture as 

soon as it is turned on. Excess moisture is dispersed throughout your home. For this reason, the dehumidifier 
should be positioned in a central and clear location so that it can draw this moist air towards it from all over 
the home. A warm hallway or landing is an excellent position for your dehumidifier. If possible, leave interior 
doors ajar to allow air circulation.      

 
Alternatively, if you have a serious problem in one area you can begin by positioning the dehumidifier there 

and moving it to a more central location at a later date. For the most effective use, run your dehumidifier 
with external doors and windows kept closed. Please note the unit should not be placed directly against a 
radiator or other heat source.  

 
Before moving the appliance the water tank should be emptied. The handle on the appliance is designed to 

aid in its movement and should not be used to support the full weight of the dehumidifier.  When carrying 
the unit, it should be kept upright and suifficiently supported from its base. The handle should not be used 
if there is any signs of damage to its fixings. 

 
When positioning your electriQ dehumidifier, ensure that it is placed clear of any obstacle that may limit the 

air movement. Place the dehumidifier on a flat dry surface.  

 
Note:

 Do not force castors to move over carpet or uneven surfaces, nor move the unit with water in the tank 

as it may tip over and spill water. 

 

 

Содержание CD12LE

Страница 1: ...LEB 12 Litres per day CD20LE CD20LEB 20 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future reference Visi...

Страница 2: ...UTANTS 4 APPLIANCE DIAGRAM 5 FEATURES 6 INSTALLATION 6 FITTING THE OPTIONAL FILTERS 6 CONTROL PANEL 7 OTHER FEATURES AND INDICATORS 9 QUICK REFERENCE GUIDE 10 POSITIONING THE DEHUMIDIFIER 11 WATER DRA...

Страница 3: ...tlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the power cord or plug is damaged Ensure the power co...

Страница 4: ...ized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information contained within it to ensure all hazards are minimized The refrigerant system...

Страница 5: ...tants include bacteria viruses dust mites and pollen Emissions from electronic office equipment Many studies including those from EPA and the University of California Berkley have reported that emissi...

Страница 6: ...Replacement filters are available from the retailer under code ACFIL CDLEX HEPA FILTER Filters are available from the retailer under code HEPA CDLEX Note Diagrams are for illustrative purposes only T...

Страница 7: ...astors and is designed to extract unwanted humidity while saving money due to it s power saving logic It features an intelligent humidistat where the desired relative humidity can be adjusted in incre...

Страница 8: ...continuously at high fan speed to remove the most moisture possible This is ideal for drying clothes UP DOWN HUMIDITY SETTING Press the UP and DOWN buttons to select the desired relative humidity lev...

Страница 9: ...ions to improve indoor air quality The relevant LEDs above the button will illuminate to show which function is currently activated LOCK Press and hold the FUNCTION button for 3 seconds to activate th...

Страница 10: ...oom with a temperature between 12 C and 20 C it will enter the defrost mode roughly every 45 minutes HUMIDISTAT CONTROL AND FAN COMPRESSOR OPERATION When the humidity of the room is 2 lower than the d...

Страница 11: ...e fan moves the air around the room ensuring the entire air in the room is processed and humidity correctly measured DEHUMIDIFY MODE This is the standard operating mode for which the desired humidity...

Страница 12: ...n for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and m...

Страница 13: ...into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosure The water...

Страница 14: ...over gently approximately every 2 3 weeks If the mesh filter is dirty hoover it if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit When filter c...

Страница 15: ...re a distance of at least 20 cm between the unit walls Airflow seems weak Are the filters dirty or clogged Please service the filters regularly as per the user manual Unit is noisy during operation Is...

Страница 16: ...unit may be defrosting The ambient operating range is between 5 C and 35 C with a relative humidity ranging from 30 to 80 For maximum efficiency use the unit between 15 C and 32 C Sometimes cold and...