background image

10 

 

 

 

QUICK REFERENCE GUIDE 

 
 Power Button: 

Press to turn the dehumidifier on and off.   

 

 

Timer

: Press the timer button, then use the  

 buttons to adjust the duration of 

the timer (1-24 hrs, start/ stop timer).  

 

If set while the unit is running

: The number will represent the number of hours the unit will operate before 

turning off. This will not be affected if the unit enters defrost mode or the tank is emptied and reinserted.  

 

If set while the unit is in standby:

 the set number represents the period in hours after which the unit will 

start. To cancel start / stop mode press the timer key again.  

 
 

Up  and  Down  Buttons:

  During  the  High  or  Low  modes  when  the  unit  is 

displaying the current relative humidity, these buttons can be used to adjust the 
desired humidity level. The desired relative humidity can be set between 35 and 
80% in 5% increments.   

 
 

SMART Mode:

 This  is designed for maximum convenience  and defaults to the ideal 

domestic  environment  humidity  level  of  50-55%  while  saving  electricity.  This  is  the 
default mode and is recommended for most users. 
   
During operation the compressor will operate until the desired humidity is reached and 
then will stop.   The fan  moves the air around the room ensuring the entire air  in  the 
room is processed and humidity correctly measured.   

 

DEHUMIDIFY MODE: 

This is the standard operating mode, for which the desired humidity can be set using 

the up and down buttons. 

 
LAUNDRY  MODE:

  When  drying  clothes  it  is  advised  for  the  dehumidifier  to  operate  continuously  with 

maximum water extraction until the water tank is full. Do not place clothes directly over any of the vents on 
the dehumidifier. Make sure that there is nothing blocking the hot air exhaust air flow and for best results 
place the laundry within 1.5 meters of the dehumidifier.  

 

 

NOTES:  

 

If a permanent drainage pipe is fitted the unit will not stop operating. Setting the desired humidity to 
around 35% is good for laundry mode, a quick drying boost, or in emergencies. It is not recommended 
for long normal operation in a domestic or office environment.  

 

To allow more moisture in the air, press the up button and set to a higher desired humidity (e.g. 60-
70%).  

 

We recommend setting the Humidity to 50-55%.  This is great for domestic operation and dry 
storage. 

 

Setting the humidity to 60% is great for personal comfort and applications where 50% RH is 
considered too dry.  

 

Setting the humidity to 70% is ideal for unoccupied properties or where an economical run is needed 
without the need to reduce the humidity further.  

 

 

 

 

Содержание CD12LE

Страница 1: ...LEB 12 Litres per day CD20LE CD20LEB 20 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future reference Visi...

Страница 2: ...UTANTS 4 APPLIANCE DIAGRAM 5 FEATURES 6 INSTALLATION 6 FITTING THE OPTIONAL FILTERS 6 CONTROL PANEL 7 OTHER FEATURES AND INDICATORS 9 QUICK REFERENCE GUIDE 10 POSITIONING THE DEHUMIDIFIER 11 WATER DRA...

Страница 3: ...tlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the power cord or plug is damaged Ensure the power co...

Страница 4: ...ized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information contained within it to ensure all hazards are minimized The refrigerant system...

Страница 5: ...tants include bacteria viruses dust mites and pollen Emissions from electronic office equipment Many studies including those from EPA and the University of California Berkley have reported that emissi...

Страница 6: ...Replacement filters are available from the retailer under code ACFIL CDLEX HEPA FILTER Filters are available from the retailer under code HEPA CDLEX Note Diagrams are for illustrative purposes only T...

Страница 7: ...astors and is designed to extract unwanted humidity while saving money due to it s power saving logic It features an intelligent humidistat where the desired relative humidity can be adjusted in incre...

Страница 8: ...continuously at high fan speed to remove the most moisture possible This is ideal for drying clothes UP DOWN HUMIDITY SETTING Press the UP and DOWN buttons to select the desired relative humidity lev...

Страница 9: ...ions to improve indoor air quality The relevant LEDs above the button will illuminate to show which function is currently activated LOCK Press and hold the FUNCTION button for 3 seconds to activate th...

Страница 10: ...oom with a temperature between 12 C and 20 C it will enter the defrost mode roughly every 45 minutes HUMIDISTAT CONTROL AND FAN COMPRESSOR OPERATION When the humidity of the room is 2 lower than the d...

Страница 11: ...e fan moves the air around the room ensuring the entire air in the room is processed and humidity correctly measured DEHUMIDIFY MODE This is the standard operating mode for which the desired humidity...

Страница 12: ...n for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and m...

Страница 13: ...into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosure The water...

Страница 14: ...over gently approximately every 2 3 weeks If the mesh filter is dirty hoover it if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit When filter c...

Страница 15: ...re a distance of at least 20 cm between the unit walls Airflow seems weak Are the filters dirty or clogged Please service the filters regularly as per the user manual Unit is noisy during operation Is...

Страница 16: ...unit may be defrosting The ambient operating range is between 5 C and 35 C with a relative humidity ranging from 30 to 80 For maximum efficiency use the unit between 15 C and 32 C Sometimes cold and...

Страница 17: ...to operate call 0330 390 3061 or complete the online form Office hours 9AM 5PM Monday to Friday Unit J6 Lowfields Business Park Lowfields Way Elland West Yorkshire HX5 9DA Recycling facilities are no...

Отзывы: