HUMIDITY LEVEL & TIMER 2 DIGIT DISPLAY
The led indicator performs the following functions:
1. When the unit is plugged in, it will indicate the humidity level of the room.
2. When the UP and DOWN buttons are pressed, it will indicate the desired
humidity currently set.
3. When the timer is programmed will show the duration.
Notes:
When humidity level is outside the normal operational parameters will show LO/HI. If ambient
humidity is lower than 20%, it will show “LO”
If ambient humidity is higher than
90%, it will show “HI”.
OTHER FEATURES AND INDICATORS
TANK FULL LIGHT
When the water tank is full, removed or incorrectly inserted the unit will stop dehumidifying, the red tank full
light will illuminate and the unit will beep. Empty the tank and reinsert it correctly to resume operation.
AUTO DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in to defrost
mode. Following completion of the defrost mode, the unit will return to the previously operating settings.
•
When the unit is running in a room with a temperature between 5
o
C and 12
o
C, it will enter defrost
mode roughly every 30 minutes.
•
When the unit is running in a room with a temperature between 12⁰C and 20⁰C, it will enter the
defrost mode roughly every 45 minutes.
HUMIDISTAT CONTROL AND FAN/COMPRESSOR OPERATION
•
When the humidity of the room is 2% lower than the desired humidity the compressor will turn off
automatically but the fan will continue to operate to ensure that the air within the room is not stale.
The unit will use only a minimal amount of energy in fan mode.
•
When the humidity of the room is equal to or higher than the desired humidity the compressor will
restart after a 3 minutes delay to protect the compressor.
AUTO-RESTART
If the unit stops unexpectedly due to the power cut, it will restart with the previous function selected
automatically when the power resumes, and the 3 minute compressor protection has elapsed.
POWER
After the unit has stopped, to protect the compressor it is not recommended to resume operation for at least
10 minutes. Operation can resume after this period lapses. When the unit is restarted there is a 3 minute
delay before compressor will start.
LIGHTWEIGHT PORTABLE DESIGN ON CASTORS
The dehumidifier is built to be compact and lightweight. The castors on the bottom of the unit make it easy
to move from room to room.
Your dehumidifier contains an advanced micro-CPU controlled device which is capable of self-diagnostics.
The LCD display may also show the error and protections codes.