Pag. 33 di 152
The X3M-D features a built-in database including all the information (
time zone rules
) which allow to
calculate the GMT and DST offsets at any time in each time zones listed in the charts. By knowing the
GMT and the DST offset, the instrument is able to convert from universal time to local time and vice versa.
The database with the time zone data is compiled from the pack distributed by
elsie.nci.nih.gov
(
tzdataXXXXX.tar.gz
) and it is integrated in the instrument firmware. Database updates are therefore
possible only by installing a new version of firmware.
5.1.3 Reset Procedure
In order to reset the Average Powers, the Maximum Demand and the Energy counters it is necessary to:
-
Enter into the programming menu by pressing the PROGRAM button.
-
Press
the
key to display the powers reset page or the
key to display the energy counters reset
page.
-
Select YES to reset, NO to skip. Resetting is confirmed by pressing the
key that executes the reset
and returns automatically to the readings pages.
-
The reset operation clears all the average powers and the Maximum Demand.
It is also possible to exit the procedure, at any time without resetting, by pressing the PROGRAM button.