background image

 

 

                      3 

Introduction 

On behalf of our entire design team, we’d like to thank you for choosing the Elecraft K3 Remote system. 

The K3/0, or a regular a K3 in ‘terminal mode’, provides a unique real time remote control experience for 
operating a K3 located in the next room, or across the country. The latest K3 and K3/0 firmware supports a 
compact remote control serial protocol that provides a 100% recreation of the remote K3 on the controlling K3. 
All local front panel VFO knobs, other controls and button actions are immediately reflected on the remote K3, 
and all display functions from the remote K3’s LCD and LEDs are immediately displayed on the controlling K3.  

When paired with the RemoteRig internet control system (also sold by Elecraft) this K3 Remote system can 
connect your local K3 or K3/0 to a remote K3 over the internet, including transmit and receive audio, without 
the need or complexity of setting up computers on each end. The K3 Remote system provides a 

real radio

 feel 

with immediate control feedback and very fast response times. The K3/0 connects to the RemoteRig unit 
through its rear connectors. It uses its internal speaker and front headphone jack for receive audio, and its front 
microphone connector for your mic input. The result is a faithful recreation of your remote K3 on the local K3 
that is hard to distinguish from operating the actual radio.  

With K3 Remote, you’ll enjoy a high degree of operating convenience, along with world-class performance - 
from wherever you may chose to operate from. Have fun! 

73, 
Eric, WA6HHQ 
Wayne, N6KR 

Terms Used in the Manual 

Remote

 

The site where the K3 and antenna system used to transmit and receive is located. 

Local

    

The site from which an operator controls the remote K3 using a K3 or K3/0.   

In the Box 

What is included in your shipment depends upon the configuration you selected when ordering. This may 
include: 

1.

 

Two RRC-1258MkII units that provide the interface to the internet; one for the remote location and one 
for the local (control) location  

2.

 

RRMTCBL cable set to connect the remote RRC-1258 unit to the remote K3.  

3.

 

K3/0 Remote control Head. 

4.

 

RRK0CBL cable set to connect a local K3/0 as the controller. 

5.

 

RRK3CBL cable set to connect a local K3 as the controller.  

See Appendices A and B for details about the cables included in each set.  If anything is missing, contact 
Elecraft as shown on page 16. 

Содержание K3-Remote

Страница 1: ...ELECRAFT K3 Remote including K3 0 OWNER S MANUAL Revision A April 4 2012 Copyright 2012 Elecraft Inc All Rights Reserved...

Страница 2: ...te Site Setup 12 Local Site Setup Using a K3 0 13 Local Site Setup using a K3 K3 10 or K3 100 14 Operation 15 Sending CW 15 Controlling a Remote KPA500 from the Local Site 15 Customer Service and Supp...

Страница 3: ...through its rear connectors It uses its internal speaker and front headphone jack for receive audio and its front microphone connector for your mic input The result is a faithful recreation of your r...

Страница 4: ...namic_dns html Once this static domain is set up you may use it as your Public External IP Address The private I P address The DNS address assigned to your service Finding Your Network Information If...

Страница 5: ...ings at the local and remote locations no further configuration is needed Go directly to the appropriate equipment setup on pg 12 13 or 14 to connect the cables to your equipment Local Control RR 1256...

Страница 6: ...Figure 1 Figure 1 3 Launch the Microbit Setup Manager you installed You should see a window similar to Figure 2 reporting that your computer is communicating with the RR 1256 unit and that it has succ...

Страница 7: ...on your LAN using the address shown Gateway This must match the I P address of the router that provides your network connection DNS Server This is normally the I P address of your router but some int...

Страница 8: ...ter If it continues to blink check to ensure the cable connectors are fully inserted and that you have a good cable You must have a steady green PWR light to proceed Figure 5 8 Open your computer brow...

Страница 9: ...on on the side menu to reinstate the screen showing all the settings to confirm that the changes were made properly 11 Disconnect the RR 1256 unit from power and your LAN and connect the RR 1256 remot...

Страница 10: ...r used at the control location 1 With a computer connected to the remote LAN router open the browser and enter the router s I P address to open the router s configuration page Figure 7 Various makes o...

Страница 11: ...wing data as shown in Figure 8 Be sure to check Enable for each entry and then click on Save Settings to save the changes Application Start End Protocol IP Address RRIG_radio 12000 12000 Both UDP and...

Страница 12: ...Owner s manual 2 Set the K3 for rear panel mic input and no bias see the K3 Owner s manual for details regardless of the type of mic used The RRC 1256 units automatically supply bias 3 Cable the remot...

Страница 13: ...13 Local Site Setup Using a K3 0 Figure 10...

Страница 14: ...14 Local Site Setup using a K3 K3 10 or K3 100 The K3 must have firmware version 4 47 or later installed...

Страница 15: ...gned function switch Since the KPA500 is all solid state there is no warm up period required so turning it off is equivalent to putting the amplifier in standby Power faults are indicated on the contr...

Страница 16: ...rs the original owner of the Elecraft product as disclosed to Elecraft at the time of order Elecraft products transferred by the purchaser to a third party either by sale gift or other method who is n...

Страница 17: ...h RR 1256 Units Power Supply Quantity 1 DC Power Cable Quantity 1 USB A to Mini USB Cable Quantity 1 RJ45 to RJ45 Cable Quantity 2 RRMTCBL Cable Set E980169 Quantity 1 E850510 Quantity 1 E850511 Quant...

Страница 18: ...18 RRK0CBL Cable Set E980207 Quantity 1 E980210 Quantity 1 E980211 Quantity 1 E850511 Quantity 1 RRK3CBL Cable Set E980210 Quantity 1 E980211 Quantity 1 E850512 Quantity 1...

Страница 19: ...19 Appendix B Cable Schematics Cables whose schematics are not shown here are wired straight through pin to pin E850510 E850511 E850512...

Отзывы: