![Elcometer BG80DL Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/elcometer/bg80dl/bg80dl_operating-instructions-manual_2377398006.webp)
3
en
3 GETTING STARTED
3.1 FITTING BATTERIES
Your gauge may be used with dry cell or rechargeable batteries. 3 x LR6
(AA) alkaline batteries are supplied with this gauge.
When the battery voltage is low the entire display will start to flash. When
this occurs the batteries should be replaced.
To fit or replace batteries:
1.
Unscrew battery compartment cover.
2.
Referring to battery polarity instructions on rear of gauge, insert
batteries.
3.
Replace battery compartment cover.
Note: Remove the batteries from the gauge if it is to remain unused for
a long period of time. This will prevent damage to the gauge in the event
of malfunction of the batteries.
3.2 FITTING THE TRANSDUCER
The transducer transmits and receives ultrasonic sound waves that the
gauge uses to calculate the thickness of the material being measured.
The transducer connects to the gauge via the cable which is connected
by screwing to the transducer.
3.3 SWITCHING ON/OFF
To switch on or off, press the on/off key
.
The gauge will switch off automatically after 5 minutes of inactivity.
3.4 QUICK START
Follow the steps in this quick start section to set up the gauge in its simplest form to measure elongation.
This quick start example uses a preset material type and does not include zeroing the transducer (because
the transducer is not zeroed, you will not be able to re-measure the fasteners at a later date - typically to
monitor relaxation of a joint over time).
Note: When positioning the transducer to measure an elongation, ensure that you place the transducer in
exactly the same position on the end of the bolt as used for the measurement of the reference length. This
will eliminate any potential sound path error caused by moving the transducer to a different location on the
Step
Task
See
1
Load the factory QUICK START setup
“Opening a Setup” on page 34
2
Select units/resolution
“UNITS” on page 40
3
Select bolt material type
“TYPE” on page 40
4
Create a group to save measurements
“Creating a New Data logger Group File” on page 32
5
Set the approximate length of the bolt
“Setting the Approximate Length” on page 30
6
Automatically locate the bolt end
“Conducting an AUTO SET” on page 30
7
Measure and save the unloaded (refer-
ence) length in column A of the group
“Measurement - Taking Readings” on page 26 and
“Storing readings in a Data Logger Group File” on
page 32
8
Apply a load to the bolt
8
Measure and save the elongation in col-
umns B to ZZ of the group
Battery
compartment
cover
5
0(18
&/5
0($6
2.
(6&